To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 440 of 5284

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

OPC UA: allow a host name override

Allow a hostname override when connecting to the OPC UA endpoint.   We have some use cases where the URL returned by two independent OPC UA servers has the same name.  This prevents the Connector from connecting to the correct endpo...
Clint Ramsey over 3 years ago in PI Connectors / PI Connector for OPC UA 6 Declined

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

OPC UA Historical data recovery

The PI OPC UA connector can manage historical data recovery when connection is lost between the OPC UA server and the connector, but if the connection problem is between the OPC UA server and the data source on field, when connection is recovered ...
JavierCastane over 3 years ago in PI Connectors / PI Connector for OPC UA 4 No status

Support Assigning Point Sources for Connectors

Connectors currently assign point sources; this is not user configurable.  In addition, all connector of like kind get the same point source.  This makes it difficult to determine which tags "belong" to which connector node.  Users ...
Brian Deslatte over 3 years ago in PI Connectors / General 2 Declined

Replicate AF Analyses with PI System Connector

I would like to have the option to replicate AF Analyses using PI System Connector with the option to mark the desired analyses for replication.
Guest over 3 years ago in PI Connectors / PI System Connector 1 Declined

PI Connector for IEC 60870-5-104 writes 'No Data' or another SYSTEM digital state when connection to the Data Source is lost.

This connector is specially used to monitor the connection of the machines, but if there is a general network crash, and the connector losses the connection to the Datasource, it will stop sending data instead of sending something to alert of the ...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 Declined

Enable or Disable single DataSource

When a datasource is actually offline and we don't want the UFL connector to keep trying uploading or connecting to it and pollute the message log . The best option would be having the stop/start enable/disable and restart options for each dataso...
Andy over 3 years ago in PI Connectors / PI Connector for UFL 3 Declined

OPC UA server failover based on watchdog tag

Gen2 PI Connector for OPC UA support OPC UA server level failover. How the Connector determine when to failover to the other OPC UA server: As per 6.6.2.4.2 ServiceLevel , this is used by the client to determine whether to connect/disconnect fro...