To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Support of complex streams with PI Adapter for RDBMS with free attribute selection

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 2 Planned

Cannot use Office365 account to enable my PI Cloud Connect account

I cannot use my Office365 account to activate my PI Cloud Connect account, because it is a compliance issue in my company to use any other account but the Office365 account to activate this.
Guest almost 4 years ago in PI Cloud Connect 0 No status

Publish a sample of code to do an histogram

Publish a sample of code to do an histogram with PiVision extensibility. There is already a sample using a unique value (arrow) but there should be an exemple for charts to help people customise their experience further.
Guest almost 4 years ago in Developer Resources / Sample Requests 1 No status

Conditional Approval

Provide more power and flexibility to who approves reports. Currently, you can set the order of approvals. It would be nice to be able to determine who or which approval track a report goes to or undertakes based on the results of the batch (IE ...
Guest almost 4 years ago in AVEVA™ RtReports 1 Declined

Send notification to next approver-group in approval cycle

Provide the possability to send notifications based on the approval-cycle status of the report. For example: In a "two-steps" approval cycle, send a notification to the final approval group when the first group approved the report.
Guest almost 4 years ago in AVEVA™ RtReports 0 Declined

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Alvaro Bilbao about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Allow session persistence to support true QoS 2 data collection and backfill of events after a data source disconnection

It appears that regarding Session Persistence (persistent vs clean session), the Adapter hardcodes setting the Clean Session Flag for the generic data source (Sparkplug doesn’t QoS 2 nor session persistence) to true. This should be a user-defined ...
Daniel Lopez 5 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Include the "Include variables having historical data only" flag for the OPC UA Adapter

The OPC UA Connector has a feature that should also be included with the AVEVA Adapter for OPC UA : UserAccessLevel=HistoryRead - No real time data to subscribe for and only has historical data stored Please add this feature to the adapter.
Joshua Weishaar 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

PI Adapter High Availability Resilience

Problem Summary: The client failover service for PI adapter is not highly available. If the client failover service node is unavailable, then the PI adapter instances that it manages will lose failover functionality. This is further exacerbated if...
GaryYegiazaryan about 3 years ago in AVEVA™ Adapters / General 2 No status