To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 21 of 5194

PI Server 2018 SP3 default Points

Please exclude the information from PI Server 2018 SP3 installation and upgrade guide, which describe to check the Default Health Points as there are no default Points created in 2018 installation.
Guest over 3 years ago in AVEVA™ PI Server / Help / Documentation / Videos 5 Declined

Add option to select interface behavior for bad timestamps (PI RDBMS)

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the interface attempts to use the current timestamp instead and logs the following error: "pitm_settime() error - 15002. Using current...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Accept weeks and years in the relative time syntax for history recovery start and end times

For whatever reason, times such as *-1w or *-1y are not accepted, but times such as *-1mo and *-1d are OK. Please make the PI Interface for RDBMS accept the same relative times that other PI programs accept.
Kenneth Barber over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

RDBMS Interface - Full Sync and Annotations

The PI SDK writes required for setting annotation values with the exdesc and RDBMS interface are not compatible with Full Synchronization. Make this compatible.
Matt Voll over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Reformat 2023 help/doc files so text not scrolling off the right hand side of page.

An example of the issue can be found in the 2023 Pi System Explorer help/user doc when searching for "Impact score". The text box goes past the edge of the page and you don't know if you are missing something important.
Steve Hampton over 2 years ago in AVEVA™ PI Server / Help / Documentation / Videos 0 No status

Documentation for differences between Operating System

It would be useful to have documented what the differences between OS versions for the PI Data Archive in terms of performance and capabilities.
Guest over 3 years ago in AVEVA™ PI Server / Help / Documentation / Videos 0 Declined

Doubt

I have a question. I am adding a PI points to Attribute templates and Default values do not change. Why that is happening? Thank you
Guest over 3 years ago in AVEVA™ PI Server / Help / Documentation / Videos 0 No status

New start-up parameter /SYNC_TIME defining a floating-window during which the interface will keep a RDB table in sync with PI data archive

The new RDBMSPI param:  /SYNC_TIME=rel_start_time,rel_end_time   for instance /SYNC_TIME=*-6h,*+1h When set, the interface: - after each execution of a query, which shall have the same "floating" window in its WHERE clause; for insta...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 1 No status

Accept the dd-mmm-yyyy format in the absolute time syntax for history recovery start and end times

The PI Interface for RDBMS currently accepts the format dd-mmm-yy but not the format dd-mmm-yyyy for history recovery start and end times. The former format lacks the century, so the year is ambiguous. The latter format solves this problem and so...
Kenneth Barber over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

History recovery from multiple tags with one output tag

I have a scan-based output point writing multiple PI values to the relational database as described here: https://livelibrary.osisoft.com/LiveLibrary/content/en/int-rdbms-v4/GUID-1A194D2B-388B-4FD7-8B82-D85EDDBBC572 I would like to perform histo...