Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Timur Eroglu over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Adapter for BACnet - defaultStreamIdPattern add ObjectName as possible parameter

Currently, for the Adapter for BACnet its [Data source parameters] defaultStreamIdPattern does not have an option to include the ObjectName in the defaultStreamIdPattern. It would be good to include this as a possible parameter for the defaultStre...
Guest 7 months ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Allow session persistence to support true QoS 2 data collection and backfill of events after a data source disconnection

It appears that regarding Session Persistence (persistent vs clean session), the Adapter hardcodes setting the Clean Session Flag for the generic data source (Sparkplug doesn’t QoS 2 nor session persistence) to true. This should be a user-defined ...
Daniel Lopez 8 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 No status

Native MQTT Publishing (Egress) to Support Unified Namespace (UNS) Architectures

Description & Use Case: As the manufacturing industry shifts toward Industry 4.0 and Unified Namespace (UNS) architectures, data must flow seamlessly between all systems in a publish/subscribe model. The AVEVA PI System is exceptional at inges...
Mandeep Sidhu 8 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Design some UI for PI Adaptors

Design some UI for PI Adaptors, so it will be user friendly to configure the data source or data reading configurations etc. It is really hard to configure or troubleshoot an issue in PI Adaptor without Proper UI.
PradeepKumar Logandurai almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 2 No status

Ability to Manage Global Notification Formats from PI Builder

Currently, there is no button in PI Builder which allows users to bring in Global Notifications Formats. The button would allow users to read in current Formats and then users would be able to Publish edited formats or newly created formats. This ...
Guest over 4 years ago in AVEVA™ PI Server / PI Builder 0 No status

Allow Adaptors to run in Docker

Allow Adaptors to run in Docker. This would ease the roll-out and management of adaptors. Also new Cisco switches now allow Docker instances on the switch, limiting the need for extra hardware.
Erik Prins over 2 years ago in AVEVA™ Adapters / General 2 Already exists

Creating more dynamic tagnames

As a system administrator, I want to make the creation of Pi points more dynamic. Each message I receive contains device data and a field indicating the originating device. I want to use these values ​​to create Pi points that reflect the message'...
Frederic Boisvert 3 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status