To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Allows to customize Rest delivery endpoint url with element informations

I would like to post notification to a custom Rest URL based on targeted element informations. For example, If the notification is linked to an element named GR01, I would like to call : http://127.0.0.1/services/notification/gr01 So I would lik...
Guest almost 4 years ago in AVEVA™ PI Server / Notifications 0 Declined

Different email formats for event start and end conditions

There is a requirement to include different information in the email body depending on whether the notification is for the event start or end. Typically, the event start email includes the start time and start values and the event end email also i...
Guest almost 4 years ago in AVEVA™ PI Server / Notifications 0 No status

Log bad timestamps for the PI RDBMS Interface

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the actual bad timestamp received from the RDB should be logged as part of the error message. This would coincide with the following e...
Guest almost 4 years ago in PI Interfaces / PI Interface for RDBMS 0 Future consideration

PI OPCtoCSV Tool: Filter by OPC ItemID

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. It is possible to filter the items by subbranch like the PI APS Connector for OPC DA interface, but unlike the APS Connector, it is not possible to fil...
Guest almost 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI AMI Itron Interface support for TLS1.3

PI AMI Itron Interface currently supports TLS1.1. Microsoft ended support for TLS1.1 in March 2020. To keep the PI AMI Itron Interface usable with latest browsers, please update to support TLS1.3.
Guest almost 4 years ago in PI Interfaces / Other Interfaces 0 Evaluating

More Database Options for PI Event Frame Generator

Allow configuration options for different databases via the PI Event Frame Generator. Being able to connect to a database via ODBC and then have a configuration file that would allow adding entries from that database as Event Frames would be very ...
Brian Rock 5 months ago in PI Interfaces / Other Interfaces 0 No status

Under the "Event Frame Search" option, give users more options for triggering on Attribute Values

When setting a notification's trigger criteria and specifying the "Event Frame Search" option, give the user more options for triggering on Attribute Values. Current options: Equal, Not Equal Suggestions: Greater Than, Less Than, Greater Than Or...
Guest almost 4 years ago in AVEVA™ PI Server / Notifications 2 No status

Notifications Time Zone Format

In Notifications 2016 R2, when configuring a custom Date format (via the TimeFormat attribute in the AF Configuration database), I would like an option to have the time zone display as EDT, PST, etc. The only option is to show it as a +/- offset f...
Guest almost 4 years ago in AVEVA™ PI Server / Notifications 0 No status

Notification delay setting similar to True For on EF Gen analysis

Allow the ability to configure a delay in sending Notifications so that they would only send if the triggering event frame is open for a configurable amount of time. This is possible at the analysis level using the True For setting; however, this...
Guest almost 4 years ago in AVEVA™ PI Server / Notifications 0 No status

efgen

Allow EFGen to use a Mix of PITAG + Text for the Creation of event frame names . Concatenate a Text + PITAG for example
valeman almost 4 years ago in PI Interfaces / Batch Interfaces 4 No status