Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

My ideas: Analytics & Calculations

Showing 323 of 4928

Modify all Analysis Expressions with Text Visualizer

Similar to the ability to open Text Visualizer by hitting 'F2' would be the ability to do the same for modifying (ALL) analysis expressions at once. This would be very helpful in copying existing expressions to other analyses or server environmen...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

Add security concept for Analytics Expressions at the analysis level

As an organization I want to keep confidential calculations secured even inside the same organization. Currently we can control Analytics  r/w access on the Database level. Often this is not enough granularity and the organization will want t...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

New analysis service installation not forcing the current one to stop

Customer would like to have the following possibility: During the installation of a new Analyses service kit pointing to a PI AF server where an analysis service is already configured, he would like to prevent the current PI analyses service from...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

Automatic recalculation on template based analysis without automatic recalculation

It should be possible to check "Recalculate analysis for out-of-order input events" if the analysis is based on a template and the re-calculation is not checked in the template. A change of the output time stamps is already possible.
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Override analysis of template based element

Currently you can override an analysis of a base template in a derived template by creating an analysis with the same name. Unfortunately it is not possible to do the same in an element that is based on a template. I do not want to create a deri...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 Declined

Trigger analysis on events since time creation of new version AF element.

Situation: Attribute of an AF element is one of the triggers for Event Frame analysis for sending critial Notifications. Currently: After creating a new version of an AF Element and setting a new value for the attribute the changed value will poss...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Confirmation Yes/No Dialogue Box When Deleting an Expression within an Analysis

Please add a Confirmation Dialogue Box e.g. Yes/No when deleting an expression from within an analysis. It is too easy to hit the X and delete an expression accidently.
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 3 Declined

Increase the discoverability of the windows that are accessible by right-clicking on the Operations pane

In PI System Explorer → Management, with the Analysis radio button selected, right-clicking in the Operations pane gives the user access to additional windows. Even though this is documented, it is not very discoverable. Users do not expect right-...
Kenneth Barber over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Add External Support for AspenTech Functions in Analysis within AF

Add support to import AspenTech functions into Asset Framework to use with Analysis.
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

Relative time in PI AF being DST-Aware

When utilizing the output timestamp relative to trigger time functionality within PI AF 2018, customer has experienced an issue where values written 12 hours before (*-12h) (ideally at 12PM/12AM, thanks to a 12 hour period) the output time will wr...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 5 Declined