Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Add option to view user's effective permissions or view CONNECT as user

For data sharing with orgs that are not PI users, they would have to be added to the existing org's tenant. In this use case it is difficult to verify that a user has correct permissions and can only see data intended for them without using a test...
Adam Bolin 6 months ago in PI to CONNECT / General 0 No status

Allow Definition of Point Attributes via OMF to PI Web API

When creating containers via OMF the PI Points are created with default Point Attributes - if these need to be changed it is a manual process to subsequently change the attributes appropriately. As OMF solutions can be easily deployed it would be ...
Guest almost 4 years ago in Developer Resources / Open Message Format (OMF) 2 No status

Native MQTT Publishing (Egress) to Support Unified Namespace (UNS) Architectures

Description & Use Case: As the manufacturing industry shifts toward Industry 4.0 and Unified Namespace (UNS) architectures, data must flow seamlessly between all systems in a publish/subscribe model. The AVEVA PI System is exceptional at inges...
Mandeep Sidhu 5 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Compare timestamps and output most recent value in child elements to parent element

From a varying number of child elements (all sharing the same template), I want to find the most recent timestamp of a same template-based attribute, and output the value with timestamp to an attribute in the parent element. In addition, constantl...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add To, CC and BCC for Notifications

Thanks for implementing https://feedback.osisoft.com/forums/555148-pi-server/suggestions/32874406-notification-e-mail-delivery-channel-to-accept-mul I would like to see "CC" and "BCC" in addition to "To". At out company the receipients of "To" s...
HolgerJoistOmv almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Allow EventFrame("Duration") to be used as an EndTrigger

I want to stop my Event Frame after an amount of time that is stored in an AF Attribute. For my use case, the amount of time from the beginning of an Event Fame is an end triggering condition. One way to do this, would be to allow the EventFrame("...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 6 No status

Pi adapter OPCua able to rename pi-tags

As per title
Rob Chew 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Tell us more

Attempting backfilling shows " Unknown Issue" and requires restarting the analysis service

Resolve the existing issue GetSecurityRights Throws NullReference Exception. This issue requires planning and time to resolve that can affect business processes.
Guest about 2 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status