Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Analytics & Calculations

Allow user to choose a variable name when using "Assign to variable" feature

First of all, the "Assign to variable" feature in asset-analytics is amazing and helps a lot with refactoring previously created analyses, so kudos and thanks! What would be even more amazing is if I had the ability to select a variable name wen a...
Alassane Seck over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Expose Analysis Service Evaluation Queue Count

For complex systems it is important to monitor the PI Analysis Service closely. The existing performance counters are helpful but we would really like the EvaluationQueueCount to be available as well. This would help determine if the EvaluationsTo...
Steve Boyko almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow Analysis to use "BadVal"

We have many cases where data is showing up as "questionable" and thus cannot be used in an analysis even tho the value is still mostly good and can still be accurately used in a calculation. Being able to choose to use these "BadValues" would be ...
JACKSON DALY over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

PI FrequencyGT function and PI FrequencyLT need to be added in AF analysis.

Please add PI FrequencyGT and PI FrequencyLT functions in AF analysis, like PI TimeGT and PI TimeLT, which find the frequency (number of times) within a range when an attribute value is greater or less than a given value.
MOUFID over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

EnableAutoBackFilling for specified AF analyses

Is it possible to enable or disable the parameter EnableAutoBackFilling for different group of Analysis in different database.   The idea is to not have same  parameter EnableAutoBackFilling for all Analysis of all databases on the same ...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Compression (with the opposite intention)

If you have a PI Tag that fluctuates within very excessive ranges, then it becomes quite difficult to observe its trending patterns in a chart because of its volatility. A feature to smooth the volatile values (i.e. exclude those outside of a use...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

Create a Flag for AFGetTrace to Show Calculation Steps for Analysis Data References

Background: Currently, the only why to troubleshoot the analysis service is to set the trace levels through the various config files.  This only works when the analytic engine is being used.  In other words, this only works if the analy...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add the Analysis Description as a column to the PI System Explorer Management

When I open PI System Explorer and click the Management button in the bottom-left I'd like the ability to show and hide certain columns of information; for example, I'd like to be able to add the Analysis Description as a column.
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Be able to resize the sections of the Functions pane in PI System Explorer

The upper edge of the blue part of the Functions pane should be resizable. If this edge is moved upwards, the entire function description can be viewed without having to scroll. If this edge is moved downwards, more functions in the list can be vi...
Kenneth Barber about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Lock to prevent certain Asset Analytics from starting

It's often convenient to bulk select all Asset Analytics and start them all, but sometimes there are some analytics you want to ensure are never started for example a Template with a rollup analysis is instantiated somewhere but has no children to...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status