Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

PI UFL Connector Event Frame Generator enhancement and bugfixes

Currently it is not possible to create an event frame from the PI UFL Connector linked to an existing element, despite the documentation does not specifically mention this restriction, you can only link the new event frame to an element created wi...
Andy about 4 years ago in PI Connectors / PI Connector for UFL 2 No status

OPC UA server failover based on watchdog tag

Gen2 PI Connector for OPC UA support OPC UA server level failover. How the Connector determine when to failover to the other OPC UA server: As per 6.6.2.4.2 ServiceLevel , this is used by the client to determine whether to connect/disconnect fro...
Ee Sheing Lee 11 months ago in PI Connectors / PI Connector for OPC UA 1 No status

New function for Ethernet/IP (“scanner”)

Add the function to able to act as (“scanner”). At this moment the connect can only act as an adapter, that means that It can't collect data from other device that also are connector is an adapter. https://www.odva.org/Technology-Standards/EtherNe...
Guest about 4 years ago in PI Connectors / PI Connector for Ethernet/IP 0 No status

Have more KPIs/diagnostics for PI System Connector

In Data Collection Manager, it would be good to have a status on Currently Synchronized Elements, Events, Tags, structure. Be able to count the events and tags that failed to synchronize since some time. Missing values in tags between source and d...
Guest about 4 years ago in PI Connectors / PI System Connector 1 Tell us more

Custom Delivery Channels in PI Notifications (newer versions)

Originally posted on PI Square at https://pisquare.osisoft.com/ideas/3778-custom-delivery-channels-in-pi-notifications-newer-versions Customer would like to have the Custom Delivery Channels in PI Notifications 2012 upgraded to the newer versions...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 7 Declined

Totalizer that resets to 0 with Asset based Analytics

I need to calculate a running sum (totalizer) of a PI Point and reset it to 0 at the beginning of each month. I would like to do this with Asset based Analytics. There are workarounds to do this, but none are great. For example, one workaround inv...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

AF/Analysis Number Base Conversion Functions

There are no number base conversion functions available in AF Analysis. There are many situations where I need to convert numbers between different 'number bases'. I frequently work with MODBUS devices and there are many times number base conversi...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 5 No status

Add a Boolean data type

Boolean variables are useful for reusing Boolean (sub)expressions, concise debugging of the value of a Boolean expression, and extraction and storage of Boolean values before writing to Int32 PI status tags (e.g. on/off status, open/closed status).
Kenneth Barber about 4 years ago in PI Connectors / PI Connector for UFL 1 No status

Be able to modify the PI Point prefix from the PI Connector for UFL administration page

It does not make sense that edits to some of the PI Connector for UFL's JSON files can be done through the administration page, but not all. The administration page should be a 1-stop configuration shop.
Kenneth Barber about 4 years ago in PI Connectors / PI Connector for UFL 3 No status

Redundancy for PI Connector Relay

Operating in a validated pharmaceutical industry, when making use of a comprehensive data/asset centralizing approach, we require the PI Connector Relay to be redundant or highly available. We are currently in the obligation to deploy the PI Conne...
Christian Leroux almost 4 years ago in PI Connectors / Other specific PI Connector 0 No status