To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 450 of 5194

host adapter(s) as a service

SaaS solution for customers with benefits thereof.
Guest almost 2 years ago in AVEVA™ Adapters / General 1 No status

Expose Analysis Service Evaluation Queue Count

For complex systems it is important to monitor the PI Analysis Service closely. The existing performance counters are helpful but we would really like the EvaluationQueueCount to be available as well. This would help determine if the EvaluationsTo...
Steve Boyko about 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Performance Tab "Jump to" Option

When trying to troubleshoot analyses and templates that may be causing poor performance on the "Management\Performance" tab, it can be tedious to locate the selected element to start determining why it's building in error count or taking a long ti...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Quadratic Regression

Add a quadratic regression function similar to "LinRegr". This would be helpful for trending relationships that are not linear, such as flow vs. pressure.
Guest about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Analysis timerule option: Add a possibility to make the timerule conservative. Emit calculation events only if the snapshot time of all inputs are more recent than the planned calculation time.

Now the TimeRules Natural and Periodic emit events to the Data PIPE in case NATURAL: an event is received by one of the selected inputs case PERIOD: when a certain timespan elapse.Both method doesn't take into account that some input of the analys...
Marco Blokdijk about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Simplify the security configuration for OPC UA

The newer OPC UA protocols have stricter security standards, which is good, but that makes configuring connections more difficult, especially with regard to the need to put in tunneling and open ports. It should be easier to establish a secure con...
Laurie Dieffenbach about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Provide a tool (in PSE?) to assist management of analytics scheduling offsets

We recommend customers use offsets to distribute scheduled calculations across time but there is not a good way manage this.Propose some utility to list a group of all scheduled analyses by same period, users supply X number of offsets and then th...
Brian Deslatte about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Provide visual indication of attributes that are used as calculation inputs or outputs

it would be useful if there were a way to easily identify which attributes represent inputs to an analytic versus those which represent outputs.
Laurie Dieffenbach about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status