To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Fix for KI: EventFrame Extended property not removed after EF is closed

The first EFs created by the PI Analysis Service after a restart can have the Extended Property StatusInAnalysisService stuck in Reconciling even after the event frame has been closed. There is a workaround to fix the issue when it occurs (see Eve...
Miranda Hill over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

PI FrequencyGT function and PI FrequencyLT need to be added in AF analysis.

Please add PI FrequencyGT and PI FrequencyLT functions in AF analysis, like PI TimeGT and PI TimeLT, which find the frequency (number of times) within a range when an attribute value is greater or less than a given value.
MOUFID about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

PI System Explorer > Preview Results: trends should allow for Inputs/Outputs to be selected/deselected

It can be difficult to clearly see the input/output trends in the prevew when trying to perform debugging. Specifically it would be useful to isolate the mapped output(s) to see if the analytic it producing the expected results. The table is usefu...
Mike Horrocks over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add TCP option to PI UFL Interface

Currently the only two options are file reading or a serial interface. But what if you have ASCII data streaming from a TCP/telnet source? The configuration would be almost the same as serial - for the connection, rather than a serial port, just n...
John Alessio about 1 year ago in PI Interfaces / PI Interface for UFL 0 No status

Expose Analysis Service Evaluation Queue Count

For complex systems it is important to monitor the PI Analysis Service closely. The existing performance counters are helpful but we would really like the EvaluationQueueCount to be available as well. This would help determine if the EvaluationsTo...
Steve Boyko over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Test Modbus Serial interface with newer Operating Systems

Currently the Modbus Serial interface supports Windows 7 as the latest possible operating system. Please test the Modbus Serial interface version 4.0.7.61 with operating systems such as Windows 10 or 11. Or release a new Modbus Serial interface th...
Rachel Morgenroth almost 4 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

WIS support for TCP Response interface

If trusts are disabled in Data Archive, the TCP Response Interface will generate a logon error every time it performs a TCP request (https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=000032778). The interface should be updated, ...
mose over 2 years ago in PI Interfaces / Other Interfaces 0 Evaluating

Prevent AutoPointSync from using SYSTEM Digital state set

AutoPointSync automatically assigns the SYSTEM Digital State set to Digital tags, this should be prevented as it can create confusion and issues down the road.
Guest over 1 year ago in PI Interfaces / General 0 No status

Enhance AutoPoint Sync APS to sychronize point sets larger than 100,000 points

https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01426 PI AutoPoint Sync is a 32-bit application an can only synchronize 100,000 points in a point source. Recommend to develop the application to use a 64-bit architecture to h...
Luke Peters almost 4 years ago in PI Interfaces / Other Interfaces 0 No status

Preserve variable-attribute mapping upon attribute path change

Currently, if a variable is mapped to an attribute and the attribute's AF path changes, the variable must be remapped to the attribute. Instead of relying on the attribute's full path to identify the attribute, each attribute should be identified...