To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

104 VOTE

Be able to disable auto backfilling on a per analysis basis

Currently in the analysis service configuration there is a parameter called “AutoBackfillingEnabled” which affects the analysis calculations in a global basis. It would be great if it were possible to disable the auto backfilling to individual cal...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 8 No status
104 VOTE

Analytics function for Last Good Value

We have come across a number of occasions where we want to bring in the last good value of an attribute as an input to an analytics.  But there is no way to do this without additional attributes and analytics.  It would be convenient if ...
taterhead247 almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 10 Tell us more

Include more details in Transfer Health Stream

The TransferStatus property of the Transfer Health Stream currently does not show warning messages generated during a transfer. It is limited to messages like "Stopped", "Started" or "Initializing". This makes it difficult for end users to detect ...
Derek Wong 2 months ago in PI to CONNECT / General 0 No status

Trigger AF Analysis Using Future Data

As an engineer, I want to execute analyses when I get a new future data value, so that any forecasts (either via Analysis or via a 3rd party system or via a PI Point update) can trigger analyses.
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 12 No status

PI Tag Mapping configuration in the background of PI OPC UA Adapter to use Point ID

The CSV / JSON file in the background will have the mapping between the OPC UA Server tag against its' respective PI Tag Name. In such case, if we need to change the tag name after sometime, then which results in multiple process like stop the Ada...
Navaneethakrishnan 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Admin Option to block check-in of linking an Analysis output to a Static Attribute

It is easy for AF Users to create a new attribute with Data Reference = None (aka Static Attribute) but then assign an analysis to update its value later. When this happens, all updates to the attribute are stored in table FindChanges_AT which can...
John Alessio 6 months ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

GUI Front End for UA Adapter

The OPC UA Adapter is a replacement for the OPC UA Connector and should thus provide similar functionality by providing a GUI.
Jonathan Brutt about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 8 In development

Variable True For parameter for Event Frame Analyses

As an AF Administrator, I want to configure an Analysis Template for Event Frames with a True For parameter that would have it's value stored in an AF Attribute (configuration item). The use case is that elements built from the template will have ...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No status

Periodic trigger monthly and yearly

I would like to have monthly and yearly periodic trigger for Analysis-Expression and Event Frame Generation. Currently I have to use the daily trigger and check in the analysis if the month or the year changed. In case of “false” there is no outpu...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 8 No status

PI Adapters should handle good NULL Values like PI Connectors and submit to the archive

A PI Connector reading a Null value in good quality send it to the Archive A PI Adapter skip the value, this gives in the archive a wrong picture. please enable the PI Adapter to submit also Null values with good quality to the archive like PI Con...
Markus Rombach 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status