To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Allowing the MQTT adapter to set PI Point attributes during the creation process

we're interested in having the ability to configure the zero, span and some other points parameters during the creation of the PI points. currently when points are created. they're defaulting to zero=0 and span=100. while also displaying Boolean p...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

AF Attribute not recongized in CONNECT transfer configuration if PI point data reference config string contains a datatype

We encountered an issue with PI to CONNECT (using current version of the Agent 2.2) not recognizing AF Attributes with PI Point Data References which have the pointtype in the data reference configuration. So that means if there is a config string...
Julian Weber about 3 years ago in PI to CONNECT / General 0 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for Structured Files - User friendly interface

Make the configuration experience more user friendly. Add a user interface for adapter configuration and management.Today, this adapter is too configuration intensive
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status

Quadratic Regression

Add a quadratic regression function similar to "LinRegr". This would be helpful for trending relationships that are not linear, such as flow vs. pressure.
Guest over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Analysis timerule option: Add a possibility to make the timerule conservative. Emit calculation events only if the snapshot time of all inputs are more recent than the planned calculation time.

Now the TimeRules Natural and Periodic emit events to the Data PIPE in case NATURAL: an event is received by one of the selected inputs case PERIOD: when a certain timespan elapse.Both method doesn't take into account that some input of the analys...
Marco Blokdijk over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Provide a tool (in PSE?) to assist management of analytics scheduling offsets

We recommend customers use offsets to distribute scheduled calculations across time but there is not a good way manage this.Propose some utility to list a group of all scheduled analyses by same period, users supply X number of offsets and then th...
Brian Deslatte over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Provide visual indication of attributes that are used as calculation inputs or outputs

it would be useful if there were a way to easily identify which attributes represent inputs to an analytic versus those which represent outputs.
Laurie Dieffenbach over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Use PI Server Alternate Display Name in stream naming pattern

The PI Server Alternate Display Name is only used to build the stream IDs. It would be better to use it in the stream naming pattern as well.