To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Performance Tab "Jump to" Option

When trying to troubleshoot analyses and templates that may be causing poor performance on the "Management\Performance" tab, it can be tedious to locate the selected element to start determining why it's building in error count or taking a long ti...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Remove requirement for shared volume for PI Analytics and PI Notifications high availibility

Our corporation has highly available PI in a number of sites. Our PI infrastructure is highly available except for Analytics and Notifications. The requirement for a shared volume for the failover cluster is not supported. We can support the failo...
Nathan Anderson over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status

Add Continue() Function To Asset Analytics

Similar to the Exit() function, a Continue() function would be very helpful in reducing the calculation load on my analysis service, in this case by not fully executing variables if a condition is true. For example, if I'm evaluating the state of ...
Kelsey Bobeck almost 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

TagTot should make use of input UOM when no output UOM is defined

TagTot will automatically account for UOM that have the time dimension as something other than per day only when the input has an assigned UOM and the function has an output UOM defined. It would be friendlier if the output UOM was defaulted based...
Mike Horrocks over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allowing the MQTT adapter to set PI Point attributes during the creation process

we're interested in having the ability to configure the zero, span and some other points parameters during the creation of the PI points. currently when points are created. they're defaulting to zero=0 and span=100. while also displaying Boolean p...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

AF Attribute not recongized in CONNECT transfer configuration if PI point data reference config string contains a datatype

We encountered an issue with PI to CONNECT (using current version of the Agent 2.2) not recognizing AF Attributes with PI Point Data References which have the pointtype in the data reference configuration. So that means if there is a config string...
Julian Weber about 3 years ago in PI to CONNECT / General 0 No status