To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for Structured Files - User friendly interface

Make the configuration experience more user friendly. Add a user interface for adapter configuration and management.Today, this adapter is too configuration intensive
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status

Quadratic Regression

Add a quadratic regression function similar to "LinRegr". This would be helpful for trending relationships that are not linear, such as flow vs. pressure.
Guest over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Analysis timerule option: Add a possibility to make the timerule conservative. Emit calculation events only if the snapshot time of all inputs are more recent than the planned calculation time.

Now the TimeRules Natural and Periodic emit events to the Data PIPE in case NATURAL: an event is received by one of the selected inputs case PERIOD: when a certain timespan elapse.Both method doesn't take into account that some input of the analys...
Marco Blokdijk over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Provide a tool (in PSE?) to assist management of analytics scheduling offsets

We recommend customers use offsets to distribute scheduled calculations across time but there is not a good way manage this.Propose some utility to list a group of all scheduled analyses by same period, users supply X number of offsets and then th...
Brian Deslatte almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Provide visual indication of attributes that are used as calculation inputs or outputs

it would be useful if there were a way to easily identify which attributes represent inputs to an analytic versus those which represent outputs.
Laurie Dieffenbach almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Use PI Server Alternate Display Name in stream naming pattern

The PI Server Alternate Display Name is only used to build the stream IDs. It would be better to use it in the stream naming pattern as well.
Clement Dekeyser over 3 years ago in PI to CONNECT / General 0 No status

New analysis to perform insert into AFTable

Hello, We have a use case that would benefit from being able to insert into an AFTable from an analysis. This would work in the same way that event frames do, where a trigger condition is meet that causes the row to be inserted. The variables from...
Trevor Flynn over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

More options when searching for PI Points

During a Lighthouse project a customer noted that they have a number of points in their data archive that are no longer on scan. It would be helpful, then, if the PI Point Search facilities in PI to CONNECT allowed use of the ‘scan on/off’ flag so...