To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Parse String Tag Using an AF Attribute as a Filter

Following the "Parse String Tag Using an AF Attribute as a Filter" KCS is a very complex setup to filter Strings based on AF Attribute values. We would like to see the filter functionality enhanced to allow filtering based on an AF Attribute Valu...
Guest about 4 years ago in AVEVA™ RtReports 0 No status

Including the name of the report parameter used in the print-out PDF's file name

It would be much easier to browse the output print-out PDF files from the RTreports generator if the file's name includes the report paramater under which the report was generated. At the time being, the report only includes a unique GUID for each...
Guest about 4 years ago in AVEVA™ RtReports 0 No status

Use a parsed value in a Trendobject

Customer wants to use a parsed value in a Trendobject. He has an an attribute in AF with several columns. He wants to use one of the values of the pipes and re-insert it in Rtreport editor as a Trendobject. At the moment, using a parsed string tag...
Guest about 4 years ago in AVEVA™ RtReports 1 Declined

AVEVA Adapter for WITSML

We need an Adapter for WITSML to get data from drilling, completions, and interventions of oil wells to CONNECT data services, so the data can be shared between multiple stakeholders.
Guest about 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Make "In" operator compatible with arrays within AF Analysis

We have many calculations following this basic pattern - take recorded values of one attribute, apply a filter (using FilterData), then retrieve values of a second attribute at the filtered timestamps of the first attribute. Currently, we cannot r...
Gregory Malek over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Overload the Convert function to allow a input UoM and output UoM for unitless values

For unitless values you can assign a unit of measure by using the Convert() function. To further convert this to another UoM in the same class you need to nest another Convert() function. For example, Convert(Convert(3600, "s"), "h")) It would sim...
Mike Horrocks over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Refrain from creating PI Points when AF Analytics is doing an expensive calcultion

If it can be known that the Analytics service is busy with an expensive calculation, the Data Archive should pause on creating PI Points, as this is also an expensive operation and may interfere with the calculation completion.
Laurie Dieffenbach over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status