To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Enable AVEVA Adapter for OPC UA to detect unchanged source values beyond a configured interval and continue sending the last known value with refreshed timestamps until a new source event is received

This enhancement is required so the AVEVA Adapter for OPC UA can functionally match ABB 800xA / Vtrin RTDB historical behavior while preserving existing PI System and Asset Framework functionality. The customer would like this capability implement...
Claudia Sischin 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA Array Support

As a PI System Administrator, I would like for the PI Adapter for OPC UA to support array data types from the OPC UA Server. A large amount of our data may be contained within arrays on our OPC UA Server, so we would not currently be able to colle...
Guest almost 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 12 No status

Add Six Sigma calculations

As a quality engineer, I need the ability to calculate Six Sigma SQC statitistics for key quality attirbutes.  Cp, Cpu, Cpl, Pp, Ppk
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

PI Analysis Performance Checker

Currently PI Analysis Service has a built-in Statistics tool in PI System Explorer. It is able to show statistics regarding Evaluation and Calculation Lag as well as Skipped Evaluations and some other important information. PI System Explorer ...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

PI Adaptor for Perfmon

To move to next gen AVEVA tech, and perform a migration to Adaptors, critical monitoring with perfmon adaptor (Instead of Interface for PIPerfMon) would be ideal. Portability of using linux, docker etc. and having this data be available in AVEVA D...
Nick Ciampa 4 months ago in AVEVA™ Adapters / New Connectivity 1 No status

Percentile function

As a user of analyses, I would like to have a Percentile function so that I can filter out atypical events when doing summary calls. The function would look like this: Percentile('attribute', 'timerange', value). This is related to enhancement req...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

Allow writing arrays as a time series to an output

I would like to be able to configure outputs in an analysis to write at multiple time points (which are defined by the result of an array function). My use case is to: 1. Configure an attribute as a Time Series Table Lookup 2. Create an analysi...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 3 Tell us more

Improve Data Cache Performance by parallelizing Data Archive update fetches

Currently, when the Data Cache is signed up for updates on multiple data archives, updates from each archive are fetched in series, one after another. When there are many data archives involved (especially if they are geographically dispersed) thi...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Enlarge area for editing analysis expressions

When editing an Analysis Expression, only 4.5 lines appear. It would helpful if more lines appeared (greater than 20 lines).
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 5 No status

Allow remote configuration

Adapters are currently only listening on localhost (127.0.0.1) causing them to be only accessible locally. For docker containers, they can only be accessed from within the container or directly on the host (with the --network host switch which res...
Gabriel Verreault almost 4 years ago in AVEVA™ Adapters / General 4 Future consideration