Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Analytics & Calculations

Showing 316

Analysis - Remove backfilling

When a failover occur or at service startup, ALL analysis configured for backfilling executes based on the last configured backfill/recalculate timerange. There is actually no feature to manually remove a configured backfill on a specific analysis.
Guest almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No Status

Include subseconds in output timestamp from variable

Currently we have an analysis with the output timestamp set to be a variable within the analysis. If I map that variable to an output, it includes the subseconds, but the output time for the analysis is truncated to the second. The output time for...
Guest almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No Status

Manage Analytics for Multiple Databases or Entire AF Server

Currently, the "Management" tab in PSE only allows you to view and manage analyses for the current AF database. Requesting the ability to select and manage analyses for multiple databases or an entire AF server without having to switch between dat...
Guest almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

Allow users to specify time zone per input

As an analysis user in a multi-national corporation with data from different time zones, I want to be able to designate a time zone per input when configuring analyses so that any relative time used in the analysis refers to the correct data.
Guest almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

Add the option to select or add custom triggers on Rollup

Currently Rollup triggers can only be "All attributes" or periodic. But sometimes, especially when you are dealing with lots of attributes been rolled up together, you may want to specify one (or a couple) attributes to the be triggers of your Rol...
Guest almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No Status

Analytics Service Utilization

The current 'Analysis Service Statistics' explain quantitatively "what is happening", but do not quantify the available capacity of the analytics engine. Managing a large and busy AF Server involves far too much guesswork as to how much additional...
Steven.Taylor almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No Status

ENable analysis scheduling with different timezone (and also DST)

it will be useful to schedule an analysis with a specific Time Zone in order to be aligned with the local time and, especially, with the local setting for DST.
ValterFostini almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No Status

Custom Delivery Channels in PI Notifications (newer versions)

Originally posted on PI Square at https://pisquare.osisoft.com/ideas/3778-custom-delivery-channels-in-pi-notifications-newer-versions Customer would like to have the Custom Delivery Channels in PI Notifications 2012 upgraded to the newer versions...
Guest almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 7 Declined

Totalizer that resets to 0 with Asset based Analytics

I need to calculate a running sum (totalizer) of a PI Point and reset it to 0 at the beginning of each month. I would like to do this with Asset based Analytics. There are workarounds to do this, but none are great. For example, one workaround inv...
Guest almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No Status

PI Tag Renaming Detection for PI Vision/PE Calculations

When input PI Tags are referenced in PI Vision 2020+ calculations, they do not automatically detect PI Tag name changes. For users with a lot of calculations, this can be extremely problematic in the event of a PI Tag name change. In the event of ...
Guest almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No Status