Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 399 of 5219

Make Analytic Expression Editor window bigger

The editor window for analytics is so small. If you create an analytic variable longer than 5 lines you have to start scrolling.
CraneHOU over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Allow BadVal to handle 'No Data' when querying before input tag creation

It is currently not possible to use BadVal and if-then-else logic to handle the 'No Data' system digital state which is returned by a formula data reference or analysis data reference attribute when one of the input tags for the calculation was cr...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Data Anomaly EF generation

Generation of EF automatically for data anomaly like bad,out of range,flatlines and spikes. A single click option which crerate EF if the data anomly occurs (based on the preset hi, lo limits) .
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Event Frame Start and End Timestamp relative to trigger

With an event frame analysis I search for production downtimes that are longer than 30 min with the "true for" option or a "TimeGE" function. But in this way I allway loose these 30 min at the beginning of my downtime event. So I would like to be ...
JanWortmann over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Output Acknowledging Event Frame to PI Tags

AF/EF is used to contextualize the OEE Event. However, because reason codes entries does not include the name of the person who entered the code and/or the time it was entered, we leverage ODBC to gain access to the Event Frame record. Due to th...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Set Reason for closed Event Frames when it is PI Point Data Reference through PI Vision

Currently, when the Reason of an Event Frame is set as PI Point Data Reference, its value cannot be changed through PI Vision Event Table. Moreover, if you try to change the Reason of a closed Event Frame and currently another Event Frame is open,...
J.M. Rodríguez over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 2 No status

have event frames with multiple start triggers match preview results when the parent start time is adjusted during reconciliation

As a PI System admin, I would like event frames with multiple start triggers to match preview results when the parent Event Frame's start time is adjusted during Event Frame reconciliation. Currently we have to take one of the following actions to...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Fix for KI: EventFrame Extended property not removed after EF is closed

The first EFs created by the PI Analysis Service after a restart can have the Extended Property StatusInAnalysisService stuck in Reconciling even after the event frame has been closed. There is a workaround to fix the issue when it occurs (see Eve...
Miranda Hill almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

PI System Explorer > Preview Results: trends should allow for Inputs/Outputs to be selected/deselected

It can be difficult to clearly see the input/output trends in the prevew when trying to perform debugging. Specifically it would be useful to isolate the mapped output(s) to see if the analytic it producing the expected results. The table is usefu...
Mike Horrocks almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

TagTot should make use of input UOM when no output UOM is defined

TagTot will automatically account for UOM that have the time dimension as something other than per day only when the input has an assigned UOM and the function has an output UOM defined. It would be friendlier if the output UOM was defaulted based...
Mike Horrocks 11 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status