To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Event Frames (EF)

Showing 62 of 4893

Store event frame start and end time as DateTime to allow sub-millisecond duration event frames

Because event frame start and end time are stored as a bigint datatype in PIFD.dbo.AFEventFrame, the precision only seems to be to the nearest millisecond. This is a problem for sub-millisecond event frames. Why aren't event frame start and end ti...
Guest about 2 years ago in AVEVA™ PI Server / Event Frames (EF) 3 No status

Add an Annotations column to the Event Frames search window

It would be nice to add an Annotations column to the search page of Event Frames, so that I can better analyze them directly from PSE for administration purposes
Guest about 2 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Keeping old events that have been manually worked on in case of Recalculation/Backfill

Case 1. There are some EFs that should be acknowledged and commented by equipment owners. In Pharma World, these comments qualify as GxP and shall not be deleted. Whereas Event Frames generated by analysis can sometimes due to data coming late or ...
Guest about 2 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

End first child event frame when StartTrigger condition no longer is fulfilled

Currently child event frames are only created when the following applies: + There's an End Trigger + There's a second Start Trigger that takes over Unlike later child event frames, the first one will not end simply because its own Start Trigger c...
Guest about 2 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Set Reason for closed Event Frames when it is PI Point Data Reference through PI Vision

Currently, when the Reason of an Event Frame is set as PI Point Data Reference, its value cannot be changed through PI Vision Event Table. Moreover, if you try to change the Reason of a closed Event Frame and currently another Event Frame is open,...
J.M. Rodríguez about 2 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Option to write EF template attribute result back into a PI-tag

Creating a possibility to populate PI-tag's based on the Events. These PI-tag's can be used in reports/displays. Generating batch, daily, hourly, shift and other "event" driven values and store them in a specific PI-tags would very easy and may re...
Guest about 2 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Use a PI tag with point type timestamp as the retrieval method on an EF attribute.

Allow the ability to collect data at specific key points within an EF. Timestamps can be saved to a PI tag via a separate analysis or to an EF via an output variable then used with the Exact Time retrieval method instead of using a relative time.
Guest about 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Gray out inherited Root Cause Event Frame category

Gray out or remove the inherited Root Cause Event Frame category to avoid having it selected. This will avoid the error " Already Exists"
Guest about 2 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Ability to relate data from pharma Tech Transfer Experiments

Ability to capture and relate data together from Pharma/BioTech Tech Transfer Labs that are running product and process experiments.  The context and data is organized around the experiment rather than by the piece of equipment.  Could...
Guest about 2 years ago in AVEVA™ PI Server / Event Frames (EF) 0 Declined

Allow EF Comments Egress via Notifications

In critical operations, managing in-field comments made on production EF's is essential to being world class. Customers need the ability to push out their field comments to surrounding systems and messaging. Most notably production critical event ...
Guest about 2 years ago in AVEVA™ PI Server / Event Frames (EF) 2 No status