To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 186 of 5259

PI Adapter for Apache Kafka

Create a PI Adapter that supports reading data from Apache Kafka. Please comment with any specific data, requirements, or use cases that this adapter would need to support!
Ellery Murdock over 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Provide a streamlined way to rename streams and push the changes to the endpoint

The current process forces the user to modify the adapter configuration (DataSource for the prefix, DataSelection for the stream name) and the endpoint (PIDA, OCS). The adapter should support modifying directly the stream name and push those chang...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / General 1 Future consideration

Parametrize the "True for x minutes" parameter in event frame analysis

It would be nice if we could reference an attribute or analysis variable to provide the value for the "True for 'x' minutes" parameter, rather than having to hard-code this value. This would be especially helpful in cases where we have numerous el...
Gregory Malek over 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Limit visibility of EF to those of which the user has read access to the primary element

Currently the visibility of Event Frames in PI Vision and elsewhere is only limited by the security of those Event Frames. As the security of Event Frames created by Analyses is dependent on the security settings of the Event Frame template (and t...
Christoph Rose over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 2 No status

Automatic Event Frame Name Reevaluation

I would like to see an option on an event frame generation analysis, probably under advanced event frame settings, that enables automatic event frame name reevaluation at the end time of the generated event frame. Right now I have event frame gene...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

PI Adapter for GE e-terrahabitat/HabConnect

We need a new robust product to support data transfer between GE e-terrahabitat/HabConnect and PI. This product would need to support the following: Highly available remote management/deployment multiple instances on a single node (to support larg...
GaryYegiazaryan over 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Adapter for RDBMS to support multiple rows with same "Timestamp" colum as IndexColumn

As of version 1.x, with the IndexColumn being specified in the dataselection, the Adapter will require that each row in the source Database to have its own unique timestamp. If there are multiple rows with the same timestamp, first value with the ...
Ee Sheing Lee over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Support System States for the Adapter for Azure Event Hubs

The data passed through the Adapter for Azure Event Hubs can be very dynamic in its configuration. It would be useful to be able to send system states to indicate bad data, and possibly the nature of that bad data. In the same way that interfaces ...
Mike Horrocks about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 2 No status

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status