Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 777 of 5192

PI AF Template Versioning

Allow for PI AF templates to be version controlled. Include the ability to revert to previous template version, or continue to use old versions for specific elements. This will reduce the risk of deployment and improve change/release management pr...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 3 No status

OPC UA Historical data recovery

The PI OPC UA connector can manage historical data recovery when connection is lost between the OPC UA server and the connector, but if the connection problem is between the OPC UA server and the data source on field, when connection is recovered ...
JavierCastane over 3 years ago in PI Connectors / PI Connector for OPC UA 4 No status

Support Assigning Point Sources for Connectors

Connectors currently assign point sources; this is not user configurable.  In addition, all connector of like kind get the same point source.  This makes it difficult to determine which tags "belong" to which connector node.  Users ...
Brian Deslatte over 3 years ago in PI Connectors / General 2 Declined

Replicate AF Analyses with PI System Connector

I would like to have the option to replicate AF Analyses using PI System Connector with the option to mark the desired analyses for replication.
Guest over 3 years ago in PI Connectors / PI System Connector 1 Declined

PI Connector for IEC 60870-5-104 writes 'No Data' or another SYSTEM digital state when connection to the Data Source is lost.

This connector is specially used to monitor the connection of the machines, but if there is a general network crash, and the connector losses the connection to the Datasource, it will stop sending data instead of sending something to alert of the ...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 Declined

Enable or Disable single DataSource

When a datasource is actually offline and we don't want the UFL connector to keep trying uploading or connecting to it and pollute the message log . The best option would be having the stop/start enable/disable and restart options for each dataso...
Andy over 3 years ago in PI Connectors / PI Connector for UFL 3 Declined

UFL Timezone Conversion

Supported timestamps are currently limited to Local or UTC timezones. Data sources may not be configurable to provide timestamps in supported formats. There currently exists no robust or simple way of converting between timezones using the UFL...
Guest over 3 years ago in PI Connectors / PI Connector for UFL 5 Declined

Row/variable information to AF Analysis errors

When we built complex analysis and evaluate in PI System explorer we get general error messages without any information where the error occurs. This makes troubleshooting painful. Adding row/variable information would already help a lot!
PhilippEven about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

if then else in Analysis still checking/executing both parts

If then else clauses are often used for input filtering for our analysis in AF. We often face the issue that analysis cause errors although the part which should not be executed according to the condition is causing errors.Example: "if BadVal('att...
PhilippEven about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Write event when data source is offline

As a PI admin I would like the OPC UA connector to write a value such as 'disconnected' when the data source is offline so that I know when the connector is unable to connect to the data source,