Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 168 of 5194

Parameter for restarting the interface if no connection to the OPC server can be established after a defined period of time

We use the Phoenix Contact Firewall with the OPC Inspector. When the OPC server restarts or breaks the connection for a few seconds, the firewall blocks all ports except port 135. After initial connection through this port, new firewall rules are ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add a configuration option to the OPC DA Interface so that the user can adjust the maximum advise tag exception delay for Event/Trigger tags

This affect to delay in Event\Trigger points. KCS: Delay in Event Points. When using Event Points, we purposefully do have a delay (if excMax is > 2 s then 2 s else 0.9*excMax) for advise tags (Trigger Point) before they're sent to the PI Serv...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add a configuration option to UniInt so that the user can adjust the minimum wait time for checking for new events from the Update Manager

This affects the delay in Event\Trigger tags. KCS: Delay in Event Points. The largest and most variable delay seems to come from the time the event is written to the PI Server and the time the interface (UniInt) picks, which is between 0ms-1,000m...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Supporting Decimal type for PI tag in PI Data Archive

For customers from special fields (eg: Pharma industry ), they would like the value to be accessed as exactly 16.168 , and would like to know if data type " Decimal " can be introduced for PI tags in PI Data Archive; Just like the following descri...
Peng Li over 2 years ago in AVEVA™ PI Server / Data Archive 0 No status

To bring back Archive Activity Grid feature

To bring back Archive activity grid which brings many insights for the administrators for archive health monitoring. My suggestion is to maybe enhance it and provide a UI base functionality, similar to PI AuditViewer.
Guest over 1 year ago in AVEVA™ PI Server / Data Archive 0 No status

OPC DA Interface to run on Microsoft Visual C++ 2015-2022

Can only install OPC DA Interface (2.7.2.20) with "Microsoft Visual C++ 2015-2019 Redistributable" installed.
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 1 Planned

Export Multiple Audit Logs into one XML/TXT File

The pidiag -xa utility doesn't support selecting a folder location and exporting the contents to a single XML/TXT file. This would be very helpful for bulk auditing actions.
Guest over 2 years ago in AVEVA™ PI Server / Data Archive 1 No status

Ability to reprocess individual points to handle digital set changes

Current functionality: When changing a point from digital set A to digital set B, all events going forward will use digital set B. If you do not reprocess the archives, the events that were archived before the digital state was changed remain asso...
GaryYegiazaryan over 1 year ago in AVEVA™ PI Server / Data Archive 0 No status

Any Patches/Updates needed to be ready for Microsoft's DCOM hardening in 2023?

By March 2023 Microsoft will enforce a patch that upgrades DCOM security. Some applications that use DCOM (such as the PI OPC interface) will require some updates to continue to work. Are there any updates that I need to apply on any of the PI com...
James_Podobea about 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Store a timestamp of when an event enters the archive database

We have a use case that could be solved very easy if we have had this as a column in the data archive. Use case: We have made PI data availible through an own made API to our clients. They use this API to fetch data from our database and into thei...
Ole Dybsjord Skarsvag about 3 years ago in AVEVA™ PI Server / Data Archive 0 No status