Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 190 of 5194

Make a way to know the statistic of use of every PI TAG in Data Archive

When you have thousands of tags in your Data Archive, you need to know wich tags are beign used and witch don't. It would be very usefull to have some diagnostic that shows wich tags are being cosumed more and from wich client.
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

Queue PI Point creation attempts if made during archive shifts

Currently, when archives are shifting, any attempts to create PI Points will be rejected with the error "Error on internal point editing call during point create for archive add point(<point info>). [-11095] Archive Shift already in progress...
Ryan Biggins 7 months ago in AVEVA™ PI Server / Data Archive 0 No status

Support Assigning Point Sources for Connectors

Connectors currently assign point sources; this is not user configurable.  In addition, all connector of like kind get the same point source.  This makes it difficult to determine which tags "belong" to which connector node.  Users ...
Brian Deslatte over 3 years ago in PI Connectors / General 2 Declined

PI Connector Relay support write modes

While writing data to PI through the connector relay there seems to be no option to control the write mode . E.g."[-109] Value at This Time Already Exists" is shown in the logs if the archive already contains an event with the same timestamp. The ...
Guest over 3 years ago in PI Connectors / General 2 No status

add interface node information in audit trail record

the audit record information only have the instance information, not have the interface node information. If the instance service id is the same, the audit information can't tell which interface node it is. The audit trail record should contain th...
Emily Ni 3 months ago in AVEVA™ PI Server / Data Archive 0 No status

Add new PIPointAttribute for "StaleTimeout"

While no customers have asked for this directly, I have seen many customers ask how to check a tag for being stale. The solution to date assumes all tags have the same staleness timeout, which really is not the case most of the time. This new "St...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 3 No status

PI Connector for IEC 60870-5-104 bi-directional between SCADA and PI

RWE Power AG “But one really important feature we need, is the ability to write back from PI into the SCADA system Until now, we couldn’t find anything about this (important) functionality. So our question is if we can use this connector bi-dire...
Guest over 3 years ago in PI Connectors / General 4 Declined

Option to remove/edit template prefix

Allow for connectors to create templates without the fixed prefix. E.g. The option to name an AF template "templatename" and not "UFL.templatename"
Guest over 3 years ago in PI Connectors / General 0 No status

Add point Type INT64, UINT64, to PI Archive

Some interfaces such as PI Modbus allow the polling of a 64-bit signed integer value or a 64-bit unsigned integer value. Yet the database does not allow you to store these values in their native formats. You must store them as a 64-bit floating po...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 4 No status

Have option to enable exception on Connectors.

There are use cases where data is sent over networks with latency (satellite link, for example) so being able to filter out noise at the connector is important.  This is also important when a connector sends data to a local PI Server in the f...
Brent Bregenzer over 3 years ago in PI Connectors / General 5 No status