Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 163 of 5194

Make it easier to get a list of buffered or unbuffered points on the PI Data Archive

For PI System Administrators, it would be nice to be able to easily get a list of all buffered or unbuffered points on the PI Data Archive. Currently, a list of buffered points is possible to retrieve using 'piartool -bfs -ptlist', but a comprehe...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Bernard Lafrance almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Incremental backups are not possible because of frequent backfilling

Occasional back filling of data would cause 5 TB of archives to be backed up with incremental backups. This is frustrating because only a few KB of data is changed in each archive. Can OSIsoft provide a way to backup only the data that has changed...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 3 No status

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Adapter for OPC UA to support Global Discovery Server

Currently, to manage the OPC UA Server/Adapter certificate, we have to manually move the certificate or get the certificate trusted beforehand. This is expected for self signed Application certificate for both the Server and the Client (Adapter). ...
Ee Sheing Lee 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Tell us more

Reprocess fixed archives to dynamic or visa versa

Currently, PI SMT will only allow archives to be reprocessed according to it's original type. User would like to be able to choose whether to reprocess the archives from fixed to dynamic or vice versa.
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 1 Declined

Add Access Right that Allow Users to Create Tags But Not Delete Tags

As a user of the PI Data Archive, I would like the ability to give users access to create tags but not to be able to delete tags. This way they will not be able to accidentally delete tags but they still have the ability to create tags.
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 5 No status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development

Apply correct localhost.tz file during PI Data Archive installation

To account for the different historical implementations of Daylight Saving Time in different regions, a localhost.tz file is added to the %piserver%\dat directory after installation. As an installer of PI Data Archive, I would like the localhost.t...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 0 Declined