To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 148 of 5193

PI collective with shared archives

Allow the Primary Data Archive server read-write access to any shared archives. All Secondary data archive servers would have read-only access. This would fix case Case # 925881. We have tags with old timestamps, for example, environmental limits,...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 0 Declined

Ability to view Instrument Tag and Point Source attributes within PI SMT > Data > Current Values pane

Feature request would be to include Instrument Tag and Point Source attributes to be view-able through the Data > Current Values pane of PI SMT.  This would allow administrators and users the ability to quickly diagnose and/or trace PI Poi...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status

PI Data Archive Installation Wizard should provide an option to restore from a backup or copy current configuration from another PI Server

As we enter 2020, the process of moving/restoring the PI Data Archive hasn't changed since its inception. Typical procedure to move a PI Data Archive on a new server is to install same version of software and then perform backup/restore of the old...
Kapil Rakh over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

Compress archives that are backed up using "Copy"

Currently, when a "copy" backup occurs, the archives are copied as-is. Archive files take up a lot of space, but they also compress very well (if you deleted a bunch of tags without creating as many new ones), and since archive backups are rarely ...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status

Improve PI Server Installation kit: disk space requirements should include the minimal PI Backup

When calculating the disk space requirements on a recent upgrade the drive was expected to have only 138 MB installed. But the install failed due to not enough disk space on the drive because the minimal backup needed a certain amount of disk spac...
Nathan Skitt over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

PI AF Link & PIBatch - Ability to uninstall it

PI AF Link is not included in PI 2018 but it would be good to be able to remove the link during an upgrade. (not possible today https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=000027668). Same for PIBatch which cannot be unins...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

AI Detection for Stale Points

As a PI System administrator, it would be helpful if the PI Server had an artificial intelligence or machine learning system which could recognize the normal updating patterns of a PI Point and report when a tag was not receiving updates properly ...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status

Use EDS to download OCS and PI data for use as a local data cache for Data Science in tools like R-Studio and Jupyter Notebook

As a data scientist, I would like to set up types, streams, and query data from OCS to use locally on my desktop in data science languages (e.g. R, Python) and tools I use (R-Studio, Jupyter Notebook) so that I can rapidly try different numerical ...
Guest over 3 years ago in Edge Data Store / Analytics & Calculations 1 Tell us more

EDS: security/authentication mechanism

Customer wants to deploy EDS at machine level to collect data from PLCs which are directly connected to the machine which would imply a proper security / authentication mechanism for EDS
Guest over 3 years ago in Edge Data Store / General 1 Tell us more

Data Retention configuration for EDS SDS

We have no information regarding data retention. This could be clarified. Data retention should be better configurable as of now, only the stream size can be configured just by estimation. Provide a sizing and calculation tool for Edge Data Store ...