Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 24 of 5194

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Allow configuration of default AF identity ProcessBook displays are shared with

By default, PI ProcessBook displays in PI Coresight are shared with the AF identity "World". Allow the default identity PI ProcessBook displays are shared with to be configurable so that it can be set to one or more identities.
Ryan McErlean over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Viewer 0 Declined

Remove parallel cursor function

If you have two graphs in one view: when you set a cursor in one graph, the same cursor is set automatically in the other graph. When you move one cursor, the cursor is also moved in the other graph – please remove this “parallel” function. We nee...
Guest over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Viewer 0 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

XY Plot support for PI-ProcessBook Viewer

Support XY Plots in PB displays viewed within Coresight.
Guest over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Viewer 0 Declined

Have event frames available for the processbook displays that are used in pi vision

have event frames available for the process book displays
Betty over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Viewer 0 Declined

Editing of the graphs (Cursor and morge functionalities)

Editing of the graphs: you can’t delete a cursor except if you completely close and reopen the view. The graph is not as easily editable as in PI Processbook. Also the zoom functions are more easy to use in PI Processbook.
Guest over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Viewer 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Accept HEX numbers for Register offsets in data selection

Most modbus equipment providers provide information using registers in Hex format i.e. 0x0000 ~ 0xFFFF. It would be nice if the offset could accept this to avoid error in conversions HEX to DEC. Would make things alot more seamless/easier.
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration