To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

processor rate(s) for Processor properties of Modbus Adapter Service Health

Visualize and understand usage when trended with other diagnostic properties.
Guest 6 months ago in AVEVA™ Adapters / General 1 No status

OMF Egress health to include stream count

Validate stream count for scenarios where there are multiple Components
Guest 6 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

option to not collect quality

Quality is not supported by the OPC UA Server/always zero.
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

The DNP3 Adapter should support group 40

The interface supports this group. The Adapter does not (see https://docs.aveva.com/bundle/adapter-for-dnp3/page/1231146.html). It is essential that the Adapter have this identical feature as the interface, to allow it to read the same data and be...
Daniel Lopez 12 months ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 0 No status

Adapter should have the ability to read from a TCP Socket

In a lighthouse project we needed to read from a TCP Socket. Ideally the Adapter for Structured Data files would be able to read from a socket and process its data.
Fabio Dani 12 months ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 2 No status

Enable subscribe using wildcard for AVEVA Adapter for MQTT

It would be handy to have the PI Adapter for MQTT to be able to subscribe to a broker by using wildcards only. Right now, we need to specify each individual topics on the data selection rule, and this eventually comes as individual subscription as...
Tombayu Hidayat almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

API to check Adapter buffer statistics

We can check buffer statistics with PI Buffer subsystem (pibufss -cfg, qs) and also with PI Connector/Relay, to verify whether Buffer is healthy, events in queue and etc.Adapter does not has any API to check this.
Ee Sheing Lee almost 3 years ago in AVEVA™ Adapters / General 1 No status

Add a parameter for the Adapter to increase the Keep-Alive wait time

Currently, there is no parameter on the Adapter side to increase the Keep-Alive wait time. It would be best to add parameter for the Adapter to increase the Keep-Alive wait time.
Alexa Derago 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Include the "Include variables having historical data only" flag for the OPC UA Adapter

The OPC UA Connector has a feature that should also be included with the AVEVA Adapter for OPC UA : UserAccessLevel=HistoryRead - No real time data to subscribe for and only has historical data stored Please add this feature to the adapter.
Joshua Weishaar about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more