Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 163 of 5192

Eliminate the need to scroll on the sign-in page

On laptops, the contents of the sign-in page do not fit on the screen, so the user must scroll to see all of it. Please redesign the page so that the content fits on the screen. Shrink or eliminate the picture of the bridge, or send it into the ba...
Kenneth Barber over 3 years ago in Customer Portal & PI Square / General 0 No status

The current OSISoft web site is not working with Microsoft Internet Explorer 11 which is the supported

Good Morning Ali, Thanks for u email. The current OSISoft web site is not working with Microsoft Internet Explorer 11 which is the supported browser in Saudi Aramco. Although we tried FireFox as well as Microsoft Edge. Both also are not supported ...
Guest over 3 years ago in Customer Portal & PI Square / General 2 No status

Allow new method(s) in the Quindar Interface

1) The Survalent System API allows references to be pulled by station, or by PointID. While Station migrates around periodically in our processes, PointID does not, and is fixed. This would reduce tag change management by greater than 50% in our p...
Guest over 3 years ago in Customer Portal & PI Square / General 1 No status

Remove Idea from Create Content on PI Square

PI Square users can still create Ideas. Remove this option or redirect to this site
JTWhite over 3 years ago in Customer Portal & PI Square / General 3 Planned

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

PI Adapter for Structured Files - User friendly interface

Make the configuration experience more user friendly. Add a user interface for adapter configuration and management.Today, this adapter is too configuration intensive
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status