To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 61 of 5200

Allow following articles to see when it is validated or has been updated

Need to ability to subscribe for updates to the article for when a fix has been found/validated - get notifications on bug status, as well as any available workarounds. This is especially important for non-validated articles
Gabriel Verreault over 3 years ago in Customer Portal & PI Square / Knowledge Base 0 No status

PI Interface for OPC DA bitmask plugin with float data type

PI Interface for OPC DA has a plugin called "Bitmask" to extract specific bits from regular OPC values that are of type Int (i.e VT_I2 / VT_I4 / VT_UI2) but other data types such as floats are not supported. It would be good to have Float data typ...
Guest about 1 year ago in PI Interfaces / PI Interface for OPC DA 1 No status

Allow automatic interface restart based on Device Status

In some cases, such as when using a tunneller, the PI interface for OPC DA requires a restart to resume collecting data. A feature that allows an automatic restart of the service based on the value of the Device status Health tag would avoid human...
Alberto Tedesco over 2 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Show votes on the latest article version on customer portal

Right now, the vote numbers on articles are cumulative; they show all of the votes the article has received over the life of the article. As a result, if there is a problem with an article, say a broken link, then it will get a lot of negative vo...
Guest over 3 years ago in Customer Portal & PI Square / Knowledge Base 0 No status

Add ability to enable email notifications for OSIsoft Alerts

As a PI System Admin, I would like to be notified via email when OSIsoft issues an alert. Currently, I have to log into the Customer Portal and check my feed to see if there is a new alert as it is only possible to enable email notifications for ...
Guest over 3 years ago in Customer Portal & PI Square / Knowledge Base 1 No status

Allow OPC DA  Output Tags to capture OOO events

Currently there is no way to send corrected values to the OPC DA Server since they are triggered by snapshot. It would be useful if there was a way to alter the values that get sent in case there are substituted/replaced values.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Automatic restart of the OPC interface whenever OPC server is restarted

whenever the OPC server undergoes any restarts or configuration changes, the OPC interface will delete all old connections, groups, etc. and it will establish a new connection to the OPC server, loading all ItemID's etc (as if it is an automatic r...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

Display the "common" product names in addition to the version numbers in Known Issues

It's difficult to know at a glance what version is affected by looking only at the long product number. It would be good to also list the product name; for example, list 2023 SP1 Patch 1 in addition to 3.9.1.0 for fixes in this version of PI Vision.
Brent Bregenzer almost 2 years ago in Customer Portal & PI Square / Knowledge Base 0 No status

Support dynamic OPC addresses

My OPC server's items have the OPC server node name included in the itemID, for example: serverA.AB_1234.PV. I have redundant OPC servers and redundant interfaces (in failover) and would like the tags to refer to the correct OPC address including ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Interface should reload performance counters after failover and keep track of them.

The interface should be designed to reload counters both at startup and when becoming the active interface after a failover. The interface should realize the counter is not available and periodically attempt to reload (ideally with a message to th...
Nicolas Capera Choconta over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status