To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Add ability to check adapter level failover status

Currently it is not possible to check the adapter failover state in the utility. Still requires using edgecmd get failoverstate to check which adapter is primary / secondary and view failover score, adapter status and last processed time.
ChrisMcKee 3 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 Evaluating

Include support for no Stream ID Prefix

Leaving the Stream ID Prefix empty in the utility for the components data source sets NULL in the .json file. This results in adding a prefix to the stream which can inadvertently cause new streams to be built in the data archive instead of sendin...
ChrisMcKee 3 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 1 Planned

Start/stop components to be retained on restart

Currently it is possible to stop a component for a running adapter. However, if the adapter is restarted the component will automatically start up. It would allow for extra control during commissioning, downtime, incidents, etc. to be able to disa...
Mike Horrocks about 1 year ago in AVEVA™ Adapters / General 0 No status

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest over 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 10 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Evaluating

Prioritize user-friendliness over reflecting the configuration file

Currently, the AVEVA Adapter Configuration Utility is a program that lets you enter data into the configuration file without having to type parameter names and while having some protection against invalid inputs (e.g. a check box for true/false va...
Kenneth Barber 4 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Custom HTTP header

add functionality so will bepossible to configure the PI Adapter for OPC UA to include a custom HTTP header when authenticating requests to the PI Web API endpoint The request for this feature recently came up in a support case for PPC (Dev CR: CR...
Dimitrios Pilos over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Add a pop-up message in ACU to let user know if StreamId does not follow adapter stream id rules

Adapter creates the streamId during discovery based on {NamespaceIndex}.{Identifier} from the data source. If streamId does not follow rules from user guide or SDS rules user may not be able to view or add streamIDs to trend in CDS. Add a pop-up m...
Guest 3 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Enable AVEVA Adapter for OPC UA to detect unchanged source values beyond a configured interval and continue sending the last known value with refreshed timestamps until a new source event is received

This enhancement is required so the AVEVA Adapter for OPC UA can functionally match ABB 800xA / Vtrin RTDB historical behavior while preserving existing PI System and Asset Framework functionality. The customer would like this capability implement...
Claudia Sischin 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Improve warning message handling for dynamic payloads in the adapter logs

When the MQTT Adapter is handling dynamic JSON payloads, there are a high number of warning messages that flood the adapter component message logs. To avoid taking up too much disk space and to make it easier to navigate the logs without digging t...