To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

AVEVA™ PI Server

Showing 1266 of 4893

Allow BadVal to check multiple inputs or IFERROR

Right now BadVal can only check one variable or Expression.  So if I am evaluating an expression with say 10 inputs, and I want the expression to output NoOutput() if any one of the 10 inputs are BadVal, then I have 2 options right now. ...
taterhead247 about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 5 No status

Reason Code value to AF element attribute or PI Tag

As a PI system user, I need the ability to use reason codes to develop reports and dashboards. The current functionality of PI Vision symbols and analytics do not really enable the use of the current data type of EF attribute. The ability to map ...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Allow EventFrame("Duration") to be used as an EndTrigger

I want to stop my Event Frame after an amount of time that is stored in an AF Attribute. For my use case, the amount of time from the beginning of an Event Fame is an end triggering condition. One way to do this, would be to allow the EventFrame("...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

Ability to change the timezone used in PI System Explorer with a feature similar to what is found in PI DataLink or PI SMT 2017.

As an end user, I would like to be able to change the timezone referenced in PI System Exporer from client timezone to server timezone. Something similar to the "PI Data Archive Time Zone"  setting found in PI DataLink would be helpful.
Guest about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 8 No status

Add support for multiple SortFields in AF Search

Currently, AF search results can only be sorted by a single field. It would be useful to have the capability to specify 2 (or more) SortField values so that the order of results can be guaranteed in the result of a tie. For example, being able to...
Guest about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

Enhance Analysis Template Search Option in PSE Management Tab

When searching by Template in PSE Management tab all analysis templates are returned in the drop down list. This can result in hundreds of options being listed depending on the size of the AF Server and database. This makes it very complicated and...
Mario Carioni 6 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Add point Type INT64, UINT64, to PI Archive

Some interfaces such as PI Modbus allow the polling of a 64-bit signed integer value or a 64-bit unsigned integer value. Yet the database does not allow you to store these values in their native formats. You must store them as a 64-bit floating po...
Guest about 2 years ago in AVEVA™ PI Server / Data Archive 4 No status

Show Child Attribute in Analysis PE Editor Auto-Complete

As a user configuring Analyses, I would the the Performance Equation (PE) Editor's auto-complete to suggest any child attributes as well as regular attributes.  Note: This was previously Enhancement 109589.
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 2 Declined

Date Format in AF Event Notification

In AF please provide a way to suppress time zone and/or to format the timestamp in AF Events, particularity, Notifications. For example, in the message format in e-mail notification I do not need to indicate the time zone it was triggered in. Ple...
Guest about 2 years ago in AVEVA™ PI Server / Notifications 3 No status

Filter Expressions for PI Point Data Refences

Allow the use of filter expressions, similarly PI DataLink Compressed Data, so that you can visualize or perform calculations on filtered data (e.g., excluding bad values, certain digital states, etc.).