To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 3248

Overload the Convert function to allow a input UoM and output UoM for unitless values

For unitless values you can assign a unit of measure by using the Convert() function. To further convert this to another UoM in the same class you need to nest another Convert() function. For example, Convert(Convert(3600, "s"), "h")) It would sim...
Mike Horrocks 6 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Copy path from value/trend out of PI Vision.

I would be happy if there was a way to copy the PI tag/AF path of a value field or trend to the clipboard. Often I need certain data points for an Excel evaluation. In Processbook, the corresponding tag could still be easily copied out via the con...
bhass about 1 year ago in AVEVA™ PI Vision™ / Display Management / Displays Page 1 No status

Use months and years with ParseTime function

ParseTime (Tag-based PE function) it does not support weeks, months or years. It will be helpful to use months and years with ParseTime function not only days.
Guest about 1 year ago in AVEVA™ PI System Access (PSA) / PI Web API 0 No status

Add the "Enable Analyses when created from template" option to PI Builder

Would like to have the possibility to edit the option: Enable Analyses when created from template, for Analysis category in PI Builder.
Eduardo Mirra Galante Miller over 1 year ago in AVEVA™ PI Server / PI Builder 0 No status

Support PI-to-Data Hub Agent configuration tool when Proxy Server is activated

It seems that if there is a proxy Server active that PI-to-Data Hub Agent does not run in "interactive" mode. It just comes up with the error message "Please log in to AVEVA Data Hub via the default system browser. If the login fails, relaunch the...
Guest about 1 year ago in PI to CONNECT / General 0 No status

PI to Data Hub to propagate Enumeration Sets

We make use of Enumeration Sets in AF to provide labels to Integer values. We need those also in ADH to view them as such.
Christian Leroux about 2 years ago in PI to CONNECT / General 0 No status

Pi Notifications should have smarts to exclude or N/A message body content for excluded attributes created from templates.

Pi Notifications should have smarts to exclude or N/A message body content for excluded attributes created from templates. Currently if we have say 4 attributes in an element template, and some instance elements have a couple of those "excluded", ...
Zubin Najmi 7 months ago in AVEVA™ PI Server / Notifications 0 No status

Batch interface to AF connection health monitoring tag

Having a health tag for batch interfaces which monitors the connection status between the interface and its corresponding AF server. This way, users can be informed if there are any issues with the interface creating event frames on AF.
Guest about 1 year ago in PI Interfaces / Batch Interfaces 0 No status

Consistent colour palettes across symbols and multi-states

Currently, the colour palette and swatches provided by multi-stating doesn't have the same selection as for the symbols. Trying to have a consistent colour scheme is hampered by this. For example, the default blue (3f7faa) used in trending is not ...
Mike Horrocks about 1 year ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status