To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ Adapters

Showing 115 of 5209

Include buffering metrics in adapter health

In the OmfEgress component in adapter health the metrics are limited to DeviceStatus, and IO rate. Another key metric for this component is the buffering state. To keep it simple it would be useful to have the number of events in the buffer. This ...
Mike Horrocks 9 months ago in AVEVA™ Adapters / General 0 No status

PI Adapter for OPC UA Array Support

As a PI System Administrator, I would like for the PI Adapter for OPC UA to support array data types from the OPC UA Server. A large amount of our data may be contained within arrays on our OPC UA Server, so we would not currently be able to colle...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 12 No status

Allow remote configuration

Adapters are currently only listening on localhost (127.0.0.1) causing them to be only accessible locally. For docker containers, they can only be accessed from within the container or directly on the host (with the --network host switch which res...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / General 3 Future consideration

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

Support https instead of http only

No description provided
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / General 2 Future consideration

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow client-level failover on a per data source component level

Currently the client-level failover for Adapters occur on a per Adapter level. Which means that for instances where multiple data sources are configured, in some circumstances failover may result in an instance with a bad connection to a particula...
Miwa Teranishi 8 months ago in AVEVA™ Adapters / General 0 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 15 Planned

Egress via AF SDK

Please add AF SDK Egress as an additional optional egress component. This would be very helpful for customers who are using the adapters, but keeping the PI Server on-premise. The adapters are relatively light-weight services; however, the “cost” ...