Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 3248

Allow EdgeCmd to set null or empty string parameter values

As per KB000042993, setting parameters with EdgeCmd that are <null> or "" (empty string) is not possible. Instead the JSON configuration file must be created and used in place. It would be more intuitive if executing commands such as: edgecm...
Mike Horrocks 3 months ago in Edge Data Store / General 1 No status

Prevent an user from approving more than once

When a report has multiple approval cycles with the same group (or with different groups that have some people in common), it would be useful to have the option of preventing the same user from completing all approval cycles, so that they must be ...
Guest almost 2 years ago in AVEVA™ RtReports / Generator 0 No status

Create a utility/script that will output the PI products installed, their versions and the most recent version of the product

Create a utility/script that will output the PI products installed, their versions and the most recent version of the product on the machine it is run on. This would help with installations and to manage the current software that is installed.
Guest about 2 years ago in AVEVA™ PI System Access (PSA) / General 1 No status

Implement FindChangedPIPoints

Add a PIServer.FindChangedPIPoint implementation to allow easily detecting changes to the point table. Today one has to periodically load all PI Points to find and react on potential changes. Especially with larger point counts these operations ca...
Guest about 2 years ago in AVEVA™ PI System Access (PSA) / PI Web API 0 No status

Ability to manage non-impersonated linked tables without PI AF Server Admin privilegies

PI AF Admin would like grant permissions for users that are not level server admins to create and edit non-impersonated linked tables. Currently this only allowed for AF server admins or using impersonated linked tables. User guide: https://liv...
Guest about 2 years ago in AVEVA™ PI Server / Security 3 No status

Mass create data source list for PI Connector

For the PI Connector for EtherNet IP you can have up to 100 data sources. Typing in all of them is tedious. It would be nice if we could copy/paste information from Excel OR have a structured import/export file to the data source list.
Dan.Louchbaum about 2 years ago in PI Connectors / PI Connector for Ethernet/IP 1 No status

PI Connector for Ethernet IP should retrieve tagnames from the PLC array

The AF Hierarchy that is created by the connector does not take into consideration any of the tagnames within the PLC array, it just creates attributes for them as slot.n where “n” is a number corresponding to the array position. Not only is this ...
Allison Muraski about 2 years ago in PI Connectors / PI Connector for Ethernet/IP 0 No status

Improve the structure of the history recovery after connector restarts to ensure that initial period of history recovery is complete

The 30-day history recovery by the connector after restarts should get activated only after the initial history recovery is confirmed to have completed successfully.
Guest about 2 years ago in PI Connectors / PI System Connector 0 No status

Allow PI System connector to actively rectify streams if point type changes are made during runtime

Point changes on the source currently necessitate a restart of PI System Connector to rectify the streams. Allow the tau framework to handle these changes at runtime without restarting the connector. Currently, if the point type changes are made ...
Guest about 2 years ago in PI Connectors / PI System Connector 0 No status

Allow rename of tags for IEC-60870-104 connector

The connector should allow sending the data to a custom tag name. The combination of ASDU and IOA are not useful to end users without the signal list. There should also be an option to automatically combine the quality flags with the value e.g. i...
sahilp about 2 years ago in PI Connectors / Other specific PI Connector 0 No status