Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

My subscriptions: AVEVA™ Adapters

Showing 92 of 4928

read files from AWS S3, Azure storage and Google Cloud Storage

For example, model inference data is written to storage and required destination is a PI System.
Guest over 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest 10 months ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest 10 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Make a BACnet/SC adapter

BACnet/SC is essentially the same as BACnet/IP... but secures the communication
Nate Anderson over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 1 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

Adapter for RDBMS to support multiple rows with same "Timestamp" colum as IndexColumn

As of version 1.x, with the IndexColumn being specified in the dataselection, the Adapter will require that each row in the source Database to have its own unique timestamp. If there are multiple rows with the same timestamp, first value with the ...
Ee Sheing Lee over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

PI Adapter for Structured Files - User friendly interface

Make the configuration experience more user friendly. Add a user interface for adapter configuration and management.Today, this adapter is too configuration intensive
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

PI Adapters should not overwrite parameters configured in the stream in ADH

When we change any override parameters for a stream in ADH an adapter restart will overwrite what we configure in the stream. One example is changing the interpolation method for a stream in ADH because we want to see the trend as step. Every time...
Fabio Dani over 1 year ago in AVEVA™ Adapters / General 0 No status