To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

My votes

Showing 5266 of 5266

Create 'Close Event Frame delay' setting

When you create PI Point Data Reference attributes in event frame templates that are used by PI Batch Interfaces, the PI Batch Interface will be responsible for resolving and capturing this PI Point data as soon as it closes the corresponding even...
Rafael Batista about 1 year ago in PI Interfaces / Batch Interfaces 0 No status

TagTot should make use of input UOM when no output UOM is defined

TagTot will automatically account for UOM that have the time dimension as something other than per day only when the input has an assigned UOM and the function has an output UOM defined. It would be friendlier if the output UOM was defaulted based...
Mike Horrocks about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Enable the configuration for VPC Endpoint when publishing a view to AWS S3

We have observed that, while the S3 Writer verification page goes through the VPC gateway/endpoint, the View publish page bypasses the VPC gateway/endpoint and uses the internet. The PI Integrator for BA does not currently establish a communicatio...
Guest about 2 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Limit rate of published changes through PI Builder

A lot of PI servers we work with have a high system load. When we create, change or delete PI Points in PI Builder we have to do a few hundred points at a time and monitor the Pending Events counter from Update Subsystem on the PI server to make s...
Robert about 2 years ago in AVEVA™ PI Server / PI Builder 0 No status

PI Vision Context Switching: Allow for all Attributes to be displayed between Elements that have differing Excluded Attributes

To summarize, context switching with a table only shows the same attributes in the base element. See below for the use case example: I have a plant that has three "Rooms" which are all using the same Template. Each "Room" has a different amount of...
Michael Wahle about 3 years ago in AVEVA™ PI Vision™ / User Experience 0 No status

PI Vision trend sampled data

Ability to set PI Vision trend/time range symbols sampling frequency.
Eduardo Miller over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Support undo/redo actions in Event Comparison displays

Similar to the main display and ad hoc workspace, allow users to undo and redo an action within Event Comparison displays. This can be accomplished using the keyboard shortcuts (CTRL + Z and CTRL + Y) and/or through a button within the display.
Amit Dutta over 3 years ago in AVEVA™ PI Vision™ / User Experience 0 No status

Using more complex calculations involving the current time ('*') variable.

I made a Pi page containing calculations from several assets in our system. The result gives a flat number. It would be even more helpful If I could slot that equation into the current time calculation formula. For example, instead of doing " '*'+...
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Allowing the MQTT adapter to set PI Point attributes during the creation process

we're interested in having the ability to configure the zero, span and some other points parameters during the creation of the PI points. currently when points are created. they're defaulting to zero=0 and span=100. while also displaying Boolean p...
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Properly configure allowed Analytic / Notification host during upgrade

When upgrading Analytics or Notifications, the installer forcefully changes the allowed host parameter in the Configuration database for the application being installed. This should not happen. There should be an additional CLI parameter (and coun...
Tyler Engelhardt about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status