Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

My votes

Showing 4924 of 4924

PI to PI interface should perform first scan so that future data can recovered

/fd parameter is only used while performing real-time scan. If scan rate is set to a higher value such as a day, the user would need to wait for the first scan (after a day) to get future data. This should be done at interface startup. For use cas...
Guest over 2 years ago in PI Interfaces / PI to PI Interface 0 Declined

Provide data validation tools to verify moving history from one PI Server to another using PI to PI Interface

There is no easy way to verify that historical data moved from one PI Server to another using the PI to PI Interface isn't missing data on the target PI Server.
Guest over 2 years ago in PI Interfaces / PI to PI Interface 0 No status

Provide the option of specifying an output file path for the processed files that is different than the input file path

Allow the user to specify an output file path for the processed files that is different than the input file path, moving the files to this "output" path after they are processed. Note: This was previously Enhancement 100038.
Guest over 2 years ago in PI Interfaces / PI Interface for UFL 0 No status

PI UFL Interface - create selected tags using EnablePointCreation parameter.

Customer noticed that tags can be created automatically, but he does not want to create all of the tags autmatically, but select which tags will be created. He wants to be able to select which tags will be created and which won't.
Guest over 2 years ago in PI Interfaces / PI Interface for UFL 1 No status

UFLDesigner should aid with visualizing the flow of control through the INI file

Currently, the UFLDesigner is focused on helping the user add content (variables, filters, actions, etc.) to the INI file. However, the UFLDesigner does nothing to help the user understand the interaction between these components. Rather than hav...
Kenneth Barber over 2 years ago in PI Interfaces / PI Interface for UFL 0 No status

Suppress the message "exception attributes corrected through the SDK read"

In the PI Interface of UFL we would like the option to suppress the message: "exception attributes corrected through the SDK read" for values of excmax larger then 9hrs.
Guest over 2 years ago in PI Interfaces / PI Interface for UFL 0 No status

Please allow to use a hex value as a delimiter, which will allow to specify a Carriage Return (0x0D) as a delimiter

While PI Connector for UFL supports FOREACH (CsvGetItem(__Message, char(13))) to allow using a Carriage Return as a delimiter, it does not support Serial input. This leaves PI Interface for UFL the only option to work with Serial input. Please al...
Guest over 2 years ago in PI Interfaces / PI Interface for UFL 1 Declined

Increase max. service ID for PI UFL Interface

According to https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=3645819457236571808-241124 , any number larger than 99 can NOT be specified for PI UFL Service ID. It would be better for us if the larger number such as 300 could b...
Guest over 2 years ago in PI Interfaces / PI Interface for UFL 0 No status

Enhance OPC server failover capability

Need to trigger failover when a watchdog tag is stale for a configurable duration.
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Modifying the functionality of Trend Advise feature for PI OPC interface

As a PI OPC Interface user I would like to get step-like trends whenever that the Trend Advise parameter is enabled (even with having large exception and compression deviations that filter some of the events) so that I don't need to enable the ste...
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status