To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Connectors

Showing 383

Custom Time Range for OPC UA History Read (Recovery)

It would be very useful for to be able to specify a custom time range to do a history read for on the PI Connector for OPC UA . The connector automatically does this recovery for time intervals that it internally identifies as gaps. However, many ...
Drew Hoffman over 1 year ago in PI Connectors / New PI Connector Request 0 No status

trend log objects (BACnet object type 20) available from the connector

BACnet trendlog object present the opportunity to buffer at the edge where the data is collected and to gracefully recover from comms outages if data collection has been impacted. I would suspect the trendlog object could be handled similarly to ...
Guest about 2 years ago in PI Connectors / PI Connector for BACnet 0 No status

Wonderware Historian Connector should store some metadata in PI tag attributes

The Description, Maximum EU, Minimum EU, Engineering Units, etc. that are stored in the Wonderware historian should be stored in the PI tags' attributes as well as the Wonderware AF structure.
Guest about 2 years ago in PI Connectors / PI Connector for Wonderware Historian 1 No status

PI Connector for Wonderware Historian should be configurable to use 'FULL' mode query

The connectors should have a standard behavior. We believe the Wonderware connector should be collecting data in the same way as the Cygnet connector by getting all the data stored in the source historian irrespective of the value change. Currentl...
Guest about 2 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Add instrumentation to the PI System Connector

Need to add instrumentation to PI System Connector wheras exposing perfmon counters (so PI perfmon can store accordingly in PI tags) on AVG data flow in events/sec for a 120 seconds time period, status of the connector, etc
Guest about 2 years ago in PI Connectors / PI System Connector 1 Declined

Adjust GE e-terraHabitat Connector to support e-terraPipeline systems

The Pi Connector for GE e-terraHabitat systems was apparently only written to support GE's Electrical SCADA systems (EMS/DMS) that are based on e-terraHabitat. They also have Oil & Gas Pipeline SCADA systems, also based on e-terraHabitat, know...
KPRoth about 2 years ago in PI Connectors / Other specific PI Connector 0 No status

Remove AF Requirement for PI Connector for OPC UA

Remove the AF requirement for PI Connector for OPC UA. Users who may only be looking to send data from PI Connector for OPC UA to Data Archive are currently forced to configure connections/security for AF as well during initial setup.
Roger Ward about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Add the ability to write to a point using an attribute other than tag name

Provide the capabilities of mapping a UFL data point to a PI tag using a PI Point attribute other than the tag name.  For example, we’ll have a data file from another database that uses a different ID than our PI point name. Could we write to...
Guest about 2 years ago in PI Connectors / PI Connector for UFL 2 No status

Add ‘No Replace’ mode to UFL Connector

Currently the only PI Data Archive ‘Store Mode’ options are ‘Insert’ and ‘Update’. I’m currently working on a project where a large quantity of data needs to be downloaded daily from the internet using the REST client node. To reduce chances of da...
Mic Paluszak about 2 years ago in PI Connectors / PI Connector for UFL 0 No status

Can we have a version of the UFL Connector that is compatible with the Data Collection Manager and the Relay?

Can we have a version of the UFL Connector that is compatible with the Data Collection Manager and the Relay? Use case would be to allow the DCM to be the one-stop shop for all connectors and would make things easier to configure and manage the ...
Guest about 2 years ago in PI Connectors / PI Connector for UFL 0 No status