Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 229

Test Modbus Serial interface with newer Operating Systems

Currently the Modbus Serial interface supports Windows 7 as the latest possible operating system. Please test the Modbus Serial interface version 4.0.7.61 with operating systems such as Windows 10 or 11. Or release a new Modbus Serial interface th...
Rachel Morgenroth about 2 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Enhance AutoPoint Sync APS to sychronize point sets larger than 100,000 points

https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01426 PI AutoPoint Sync is a 32-bit application an can only synchronize 100,000 points in a point source. Recommend to develop the application to use a 64-bit architecture to h...
Luke Peters about 2 years ago in PI Interfaces / Other Interfaces 0 No status

Device status tags do not show OPC DA server Invalid client handle errors

When OPC DA interface receives an "Server returned Invalid Client Handle" error, device status tags do not show that error and therefore potential situations where data is not being received by the interface are missed I would be good that device ...
asanzacedo 9 months ago in PI Interfaces / PI Interface for OPC DA 0 No status

RDBMS time stamp precision

Currently the ODBC connection is configured with a SQL date time parameter when retrieving the TS parameter (snapshot time stamp). Due to the fact lots of sources system having more precision in their time stamps, it makes it hard to compair sourc...
meierke1 over 2 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Define more explicit system requirements for PI Interfaces

Define more explicit system requirements for PI Interfaces. According to a customer, despite the Buffer and Bandwidth Calculation Spreadsheet, currently available information does not allow for accurate hardware sizing.
Guest over 2 years ago in PI Interfaces / Installation 0 No status

PI ICU should not allow PItoPI COLD failover configuration

As of version 3.8.1 COLD failover is no longer supported by the PI to PI Interface (https://techsupport.osisoft.com/Troubleshooting/Enhancements/19255OSI8). However, the PI Interface configuration utility still allows COLD failover to be selected....
Guest over 2 years ago in PI Interfaces / PI to PI Interface 0 No status

Source and destination tag mapping list

Customer would like the ability to have PItoPI create a list of tags that includes the FULL name of the source tags, as well as the destination tags they are mapped to.  This will greatly assist in managing tags that are being sent to a remot...
Guest over 2 years ago in PI Interfaces / PI to PI Interface 0 No status

PI UFL Interface can read input files from non-UNC paths such as Azure File share

I would like the PI UFL Interface to be able to directly read from input files that are in non-UNC paths such as Azure File share, so I do not need to periodically copy the input files into another path.
Guest over 2 years ago in PI Interfaces / PI Interface for UFL 0 No status

PI UFL Interface to extract data from csv files from multiple sub-folders within the main folder.

In case of csv files in subfolders within Main Path for UFl, PI UFL Interface should be able to search the csv files with placeholder and extract data from csv files from multiple sub-folders within the main folder.
Guest over 2 years ago in PI Interfaces / PI Interface for UFL 0 No status

Manage interface names with service ID

As a PI system administrator, I would like to use the service ID to define the interface name so that I can organize and manage my interfaces more efficiently. I am currently able to do this with PItoPI but not UFL x64. Ideally, I would like to d...
Guest over 2 years ago in PI Interfaces / PI Interface for UFL 1 No status