Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 302

PI Event Frames Interface Manager

Hello, the PI Event Frames Interface Manager application must be run in the same machine that hosts the PIEFGen interface. This is an issue regarding our security rules because, the PIEFgen interface runs in secured machines and we don't want to a...
Guest almost 2 years ago in PI Interfaces / Batch Interfaces 0 Declined

Enhance how batch interfaces write to the message logs

Batch interfaces should write their messages to the message logs using the Source1 and Source2 fields just like UniInt based interfaces. Currently, batch interfaces leave these 2 fields blank. Source1 should contain the process name or similar and...
Guest almost 2 years ago in PI Interfaces / Batch Interfaces 0 No Status

Fix MAXSTOPTIME parameter for batch interfaces

The MAXSTOPTIME parameter for batch interfaces does not kill the interface process when the limit is exceeded, however the parameter does work for UniInt based interfaces. Please fix the batch interfaces so that the interface process is killed onc...
Guest almost 2 years ago in PI Interfaces / Batch Interfaces 0 No Status

BACNet: Add support for Conversion Factor PI Point attribute to PI Interface for BACNet

Add support for Conversion Factor PI Point attribute to PI Interface for BACNet. Note: This was previously Enhancement 118928.
Guest almost 2 years ago in PI Interfaces / Other Interfaces 0 No Status

Create a user friendly OPC HDA Tool to replace the current one

No description provided
Gabriel Verreault almost 2 years ago in PI Interfaces / Other Interfaces 0 No Status

Buffering Manager - add metrics for each buffered interface

When validating/troubleshooting data flow issues, it would be helpful to see metrics on which interfaces are actively sending data to the buffering subsystem via Buffering Manager. If an interface is in a bad state or stopped, it would be obvious ...
Guest almost 2 years ago in PI Interfaces / Other Interfaces 0 No Status

Fix PI XMLTool (bundled with PI Interface for OPC XML-DA)

The PI XMLTool that is bundled with the PI Interface for OPC XML-DA does not function with Windows Server 2019 even though the PI Interface for OPC XML-DA itself is documented to function. Can the client tool please be worked on so that it will fu...
Guest almost 2 years ago in PI Interfaces / Other Interfaces 0 No Status

EFGEN multi language support for event frame name

Hi, Existing EFGEN does not seem to support multi language (Double bytes characters) inputs for Event frame name. This result in the event frames names are being recorded in English char only. Would it be possible to implement the multi-langua...
Guest almost 2 years ago in PI Interfaces / Other Interfaces 1 Declined

Make the ICU maximize button work.

Clicking the maximize button in the ICU makes it take up the whole screen but the fields remain the same size. If the fields resized as well, it would make reading and entry in some of the smaller fields easier.
rphilp1 11 months ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 1 Declined

Supress PI-APS messages for Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table

Seeing "information" messages in PI-SDK related to "Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table" which is irrelevant to see in the logs. If one source instance sending to multiple destination instances...
AshwinC about 1 year ago in PI Interfaces / PI to PI Interface 1 Future Consideration