To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 5005

Single Gauge with Multiple Values

Configure gauges using multiple attribute values. As an example, if you have a tank that has 2 level sensors, it would be helpful to show both levels in 1 gauge. Currently we accomplish this by creating 2 gauges and putting 1 on top of the other, ...
holemn over 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Plot markers for all archived events for step tags

When plotting a tag with the "step" attribute on in a PI Vision trend with the scatter plot trace option, not all archived events are shown. A workaround is to create a Formula Data Reference attribute in AF that points to the tag with the stepped...
Guest over 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Scan only when the data folder changes

Specifying the scan time seems unnecessary. Instead, the PI Connector for UFL should only scan the data folder if a change to the data folder's contents is detected. Surely some sort of event listener can be set up to achieve this?
Kenneth Barber over 2 years ago in PI Connectors / PI Connector for UFL 0 No status

Allow UFL Connector to show status when HTTP request fails

This enhancement would allow the UFL Connector to be able to write a status to it's tags when a HTTP request fails, such as 401 or 503.  Currently, a bad HTTP request will fail before attempting to parse with the .ini, so  there is no ...
Guest over 2 years ago in PI Connectors / PI Connector for UFL 0 No status

Configurable OSIsoft\PI Connectors\UFL.ConnectorHost\ location defined during installation

Currently, the folder is created by default in %ProgramData%, which means that the output folder, storing the processed file, is created in %ProgramData%\OSIsoft\PI Connectors\UFL.ConnectorHost\Output\{DSName}\. Since %ProgramData% is generally o...
Gabriel Verreault over 2 years ago in PI Connectors / PI Connector for UFL 1 No status

UFL Connector - Add elements and attributes to existing AF hierarchies

Simply, it would be nice if the UFL Connector could add to existing elements and attributes already in place instead of creating a new hierarchy. Also, would like the ability to create sub-elements from the UFL connector that span multiple eleme...
Guest over 2 years ago in PI Connectors / PI Connector for UFL 0 Declined

The UFL Connector should have a run once mode

Many rest APIs allow access to historical APIs. This is data that should be collected only once when, for example, a new piece of equipment is being added for data collection. This one time data collection is currently tricky in the UFL connector ...
Guest over 2 years ago in PI Connectors / PI Connector for UFL 0 No status

Allow users to rename PI Connector for UFL point source

PI Connector for UFL allows for configuring point prefix, but does not allow for modifying point source. Some users prefer browsing tags by point source, and may want separate point sources for different UFL connectors.
Guest over 2 years ago in PI Connectors / PI Connector for UFL 2 No status

Add Mod10 to Custom Data Type Manipulator for Modbus Interface

Please add support for SquareD Mod10 custom datatype to the Modbus Interface. Schneider Electric uses a custom datatype that uses four 16 bit registers. Each register represents an integer. Each integer is then multiplied by a factor and all resu...
Guest over 2 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Allow PI Web API Admin Utility to run silently

We use the command following command to run the PI Web API Admin Utility silently in order to automate SSL certificate updates: OSIsoft.REST.Admin.exe --f=C:\temp\InstallationConfig.json --suppressUI=0 --verbose If the admin utility crashes, this ...
Guest 10 months ago in Developer Resources / General 1 No status