Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 5223

Add documentation on architectural best practice

When setting up PI to Connect Agent transfers, we need to emphasize in the documentation that we recommend installation of the PI Agent on the same network, and in the same physical location, but not on the same server as the PI server it will be ...
Guest about 1 year ago in PI to CONNECT / Help / Documentation / Videos 0 No status

‘Star Trek Medical Dashboard’ style Gauge

a ‘Star Trek medical dashboard’ style moving analogue gauge would align with the recommendations within “ ANSI/ISA-101.01-2015 Human Machine Interfaces for Process Automation Systems, ISBN 978-1-941546-46-8 “, which gives guidelines on the creatio...
Guest about 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Add a description column to the tag search results

When searching tags, it would be helpful to list the description in the result (and any other fields). I know you can hover over the tag to get a description, but when there is a long list it would be better to just show the description in each li...
David McBride about 2 years ago in AVEVA™ PI Vision™ / Search 0 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Optimize the attachments table in the PIVision SQL database

The attachments table in the PIVision SQL seems to have 1 line for each image, even if the same image is used multiple times (on different displays or even in the same display). This causes our attachments table to represent more than 50% of the s...
VMichiel about 1 year ago in AVEVA™ PI Vision™ / Administration 0 No status

Add parameter "Max Monitored Items per Subscription"

The connector for OPC UA includes a parameter “Max Monitored Items per Subscription”, which is very helpful in managing UA servers which may have limits on the maximum items per subscription. This parameter needs to also be available in the adapters.
sahilp about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

Time range configurable to attribute value

Allow the time range (either start time or end time or both) in Pi Vision to reference an attribute value. This would allow data to dynamically update according to an event. For example, I want to see a list of batch information (start time, end t...
Guest over 1 year ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Rate of change calculation is required for analysing points

Rate of change calculation is required for analysing points, especially steam parameters like temperature and pressure. This is required for fatigue analysis. For a selected time frame, the following four calculations will be required: 1) Maximum ...
AK over 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Provide additional features to support debugging

When first setting up the agent, there can be scenarios where there a number of errors to work through - for example tag not found. Summarization of errors and an alternative to event viewer would aid debugging.