Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

PI Connectors

Showing 331

Need to start/stop individual data sources

When going in the PI Connector Admin page in the data sources page, we cannot start/stop individual data sources listed when there is more than one. To stop one you need to stop all the data sources listed.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Give the ability upload different Tag Naming files in DCM / OPC UA Connector

When uploading a "Tag Naming" file in DCM, this file completly replace the existing Tag naming. It mean that a Tag naming file must be done for all datasources within one connector. It would be a lot more easy when dealing with a large number of t...
Fred_EYRAUD over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

PI Connector Relay support write modes

While writing data to PI through the connector relay there seems to be no option to control the write mode . E.g."[-109] Value at This Time Already Exists" is shown in the logs if the archive already contains an event with the same timestamp. The ...
Guest over 3 years ago in PI Connectors / General 2 No status

Create child Event Frames

UFL connector can create child element using StoreElement function. it should be useful to extend functionality to event frames on function StoreEventFrame
Carlo Pedroli over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

PI OPC UA Connector - point attribute based configuration

We are just starting the first tests with PI OPC UA Interface. We notice that the classic method of tag configuration, known from the interface, is no longer possible. This is probably due to the connector concept. Unfortunately, this does not fit...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Allow specification of PI Point Attributes set by the PI Asset Connector for Emerson DeltaV 3.X

The PI Asset Connector for Emerson DeltaV 3.X sets PI Point Attributes either based on the values in the enterprise historian configuration file (EntHist.xml) or based on default values. It would be useful to have the option to adapt the PI Point...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 2 No status

Option to remove/edit template prefix

Allow for connectors to create templates without the fixed prefix. E.g. The option to name an AF template "templatename" and not "UFL.templatename"
Guest over 3 years ago in PI Connectors / General 0 No status

OPC UA Connector Trend Advise Option

OPC UA Connector Trend Advise Option, such as in the UniInt interfaces
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 5 No status

Have option to enable exception on Connectors.

There are use cases where data is sent over networks with latency (satellite link, for example) so being able to filter out noise at the connector is important.  This is also important when a connector sends data to a local PI Server in the f...
Brent Bregenzer over 3 years ago in PI Connectors / General 5 No status

Enable Relay/DCM to allow control over the data streams and destination PI Systems

Currently the Relay will send all data streams to all routed destination. This does not allow customers to have control over what data streams go to a specific destination. The only workaround is to have independent Connector/Relay pairs with spec...
Nico Cha over 3 years ago in PI Connectors / General 1 No status