Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 727

Option to replicate PI Point security attribute with PI System Connector

The current version of PI System Connector does not support replicating the PI Point security attributes: •Point Security •Data Security •Data Access •Data Group •Data Owner •Point Access A further option would be to automatically create an...
Guest over 3 years ago in PI Connectors / PI System Connector 1 Declined

Setting of parameters k and w for IEC 60870-5-104

Parameters k (Maximum number of outstanding I format APDUs) and w, cannot be adjusted, while vendors recommend customers to set it to k=12 and w=8
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

PI Connector for Modbus TCP - include option to configure response data byte size by register type.

Certain RTUs limit the number of Boolean/Discrete values they return independently of the number of floats they return. The PI Connector for Modbus has a configuration option for “Maximum Response Data Bytes” but it applies to all register types. ...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 Declined

X509 User Token Policy

Allow future releases of the OPC UA Connector to support user authentication via certificate or IssuedToken instead of only through user/password or anonymous connection.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Scan only when the data folder changes

Specifying the scan time seems unnecessary. Instead, the PI Connector for UFL should only scan the data folder if a change to the data folder's contents is detected. Surely some sort of event listener can be set up to achieve this?
Kenneth Barber over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

Enhance pitopi.ini sections to include point source to make them unique

The pitopi.ini file is used by the pitopi interface for collecting data from multiple sources and to save other miscellaneous settings such as 'histonly' flags. The configuration ini file uses sections to separate settings between instances with a...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 2 No status

PItoPI should give indication when it is stuck querying a corrupt source archive

Currently, PItoPI interface can get "stuck" if it is querying a source data archive that is corrupt with no indication that this is what's happening.  It appears to be sending data to the destination server, but no data is received.  It ...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 1 No status

Support Analysis Backfill of Source Tag

Many of our source tags sending data to a central Data Archive are populated with data from analyses on the source AF Server. This creates two problems when we perform a backfill that recalculates data over a specified timespan for the source tag:...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status

Enhance element creation to use user defined element templates

The interface can automatically create an element at each level of event frames, but the elements do not derive from a template and there is no way to specify any attributes on the element. The enhancement request is to create elements that are ba...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

PI EMDVB Interface - Rename Parsed Files

PI EMDVB Interface - Rename Parsed Files.  Files that get renamed to .999 is no longer available with PI EMDVB.  This file renaming feature was very useful from a system maintenance perspective.  We would easily remove .999 from the...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined