To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 1675 of 5193

Enhancement for Advise tags to poll  OPC server when Excmax expires

Currently, when an advise tag does not get a value in an ExcMax period,  the interface will send the same value to PI over again without going to the OPC server (assuming that the OPC interface has not disconnected from the OPC server during ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 3 No status

Batch Framework Interfaces - [TIME] placeholder should consider whether TS=LCL is configured

Batch Framework Interfaces - [TIME] and [TIMESTAMP] placeholders should consider whether TS=LCL is configured (meaning the interface is processing incoming events as Local Time). Currently, values of these placeholders always show up as GMT timest...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 5 Planned

Support Werum PAS|X 3.2 and PAS|X Data Access (PDA)

Werum has recently released the next version of their PAS|X Database, and it bolsters a new method of Data Access. OSIsoft will need to release an re-tooled version of their PI Interface for Werum PAS|X to support this latest Werum version and the...
Ellery Murdock over 3 years ago in PI Interfaces / Batch Interfaces 1 No status

Store bad quality from OPC XML DA Server

Enhance the OPC XML DA Interface to store bad quality values from its OPC XML DA Server in PI, so that the values, timestamp and status from bad quality data are saved in PI. Note: This is work item 21742OSI8 - Add support of data quality.
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Encrypt trafic between interfaces/connectors and the Data Archive

Add an option to encrypt trafic between interfaces/connectors and the PI Data Archive
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status

Update the CA ISO interface in preparation for the upcoming API V8 deployment

CA ISO is planning to upgrade its ADS (automated dispatch system) to version 8. This upgrade introduces breaking changes from the current system, API version 7. The CA ISO interface should be updated to account for these changes.
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status

Add single scale option for PI AF trending

Currently in PI Asset Framework, trending PI Points will default with a display with multiple scales. There should be the option to change the display to view the trend with a single scale making it easier to identify differences with multiple PI ...
Dan Benedict about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Move Auditviewer function away from local PI System access

I want to run the Auditviewer function as a unprivileged remote user, moving away from the current requirement to run as a local user on the PI Data Archive Server.  This is so I can minimize security risk associated with local user access on...
Guest over 3 years ago in AVEVA™ PI Server / Security 1 Declined

Provide a central point to manage the security for the whole PI System

Instead of having several admlin tools to manage the security for data archive, AF, PI Vision, PI Integrators Could you provide a centralized security management interface which could manage all the existing and upcoming OSIsoft tools
jerome.boudon over 3 years ago in AVEVA™ PI Server / Security 1 No status

Allow Rollup analysis to output to to an Analysis Data Reference

I would like there to be a way to output the results of a rollup analysis to an Analysis Data Reference, so that I can view a trend without having to write to a PI point. Currently, there is no option to have a rollup analysis that does not write ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 7 Declined