To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4928

Improve DNP3 Output performance

Currently DNP3 outputs are done one event at a time. We could improve performance by either supporting multiple DNP messages per TCP packet or multiple analog output commands per DNP message.
Nico Cha over 2 years ago in PI Interfaces / Other Interfaces 0 No status

PI PerfMon interface to support ArcReplace

Right now PerfMon only supports ArcNoReplace. PerfMon has a history of failing over if a server is unreachable. And since PerfMon only supports Hot failover, every time it fails over the new interface tries to write values that the old one already...
taterhead247 over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Add -f (Ping Switch) to OSIsoft Ping Interface

Enhancement for Ping Interface to add -f switch 'Set Don't Fragment flag in packet. When sending large packets we do not want to Fragment. Case: When monitoring a site ping worked for small packets, however with large packets sent, the site show...
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Determine the packet loss of the ping (Ping Interface tag) out to another tag

Scenario: I have a tag that pings site A. I have the response times, which quantifies the response times of the network, but this line is also a bit slow and we suspect packet loss, but I want that in a tag.
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Expand failover functionality in Schneider-Electric Foxboro fxbais interface

Failover mechanism in fxbais (Schneider-Electric PI interface for Windows) doesn't lead to a failover when the primary interface node loses connection to the network (f.i. when its NIC fails). It just starts buffering and sends its data after the ...
Guest over 2 years ago in PI Interfaces / Other Interfaces 1 No status

Davis to Pi Interface - Additional sensor functionality

Add functionality for the Davis to Pi Interface to read additional sensor data points. The Davis to Pi Interface does not support the use of additional sensors, such as a second or third temperature sensor. The Davis console supports additional se...
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status

PI Buffer Subsystem doesn't use the user who is logged in

PI Buffer Subsystem must have a option to set up the user account is logged instead of using Windows Domain or Local account that is running the windows service. This is a huge security issue when using Buffer on client computer to send manual dat...
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status

GE HabConnect interface support for both IGNORExTH and IGNOREFLDMSEC

PI ICU rejects options IGNORE5TH and IGNOREFLDMSEC at the same time. When modeling teams change MEAS fields often, IGNORE5TH is extremely useful to keep data history contiguous. When using field time that is stamped by the EMS, milliseconds are no...
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Streamlined management of PI Interface for SNMP .pwd file

When using the interface to gather data for hundreds of SNMP devices, managing the .pwd file becomes very burdensome due to an inability to format the file. Comments are helpful in sorting devices, but they are removed upon encryption. It would be...
Guest over 2 years ago in PI Interfaces / Other Interfaces 1 No status

Create a migration path for AMI Interfaces when PI Server is moved to a new machine/hostname

Currently, AMI Interfaces require a rebuild of the AMI cache files when the PI Server is migrated to a new machine/hostname (Although to clarify if the hostname does not change during the PI Server migration the cache does not need to be rebuilt)....
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status