To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ Adapters

Do not have data entry where only 1 choice is allowed (e.g. component type when adding a new component)

In the AVEVA Adapter Configuration Utility, when you try to add a new component to an AVEVA Adapter, you get a dropdown menu for the component type. However, there is only 1 choice: the AVEVA Adapter component type. The only required instance of t...
Kenneth Barber 29 days ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

For PI Points created by AVEVA Adapters, use the point class "base" instead of "classic" if the PI Point does not use "classic"-specific PI Point attributes

When an AVEVA Adapter creates a new PI Point, it always uses the point class "classic", even if none of the attributes that are specific to this point class are ever used. Instead, AVEVA Adapters should create PI Points using the point class "base...
Kenneth Barber 30 days ago in AVEVA™ Adapters / General 0 No status

Be able to configure history recovery through the AVEVA Adapter Configuration Utility for AVEVA Adapters that support history recovery (e.g. OPC UA, RDBMS)

This is item #3 of this suggestion, posted as its own suggestion.
Kenneth Barber 30 days ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

AVEVA Adapter for MQTT to support payload compression from the source MQTT SparkplugB device

AVEVA Adapter for MQTT (SparkplugB data source) to support payload compression from the source MQTT SparkplugB device. Compression can be enabled at the Edge, for example Enable compression and/or aliasing at the Edge: For compression, either the ...
Ee Sheing Lee 4 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 No status

Include buffering metrics in adapter health

In the OmfEgress component in adapter health the metrics are limited to DeviceStatus, and IO rate. Another key metric for this component is the buffering state. To keep it simple it would be useful to have the number of events in the buffer. This ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / General 1 No status

Be able to configure the Client Failover Service through the AVEVA Adapter Configuration Utility or a separate optional GUI program

The Client Failover Service suffers from the same issues as AVEVA Adapters before the AVEVA Adapter Configuration Utility was released: you need to constantly check against the documentation and make sure that you spelled parameters and their valu...
Kenneth Barber about 1 month ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Bitmask Functionality in AVEVA PI OPC UA Adapter

During the migration from the PI OPC DA Interface to the AVEVA PI OPC UA Adapter, we noticed that the ability to apply bitmasks to incoming values is no longer supported. This functionality is critical in many existing implementations, especially ...
Dennis Fendel about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 Future consideration

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Gabriel Verreault about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 17 Planned

Enable AVEVA Adapter for OPC UA to detect unchanged source values beyond a configured interval and continue sending the last known value with refreshed timestamps until a new source event is received

This enhancement is required so the AVEVA Adapter for OPC UA can functionally match ABB 800xA / Vtrin RTDB historical behavior while preserving existing PI System and Asset Framework functionality. The customer would like this capability implement...
Claudia Sischin 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Support https instead of http only

No description provided
Gabriel Verreault about 4 years ago in AVEVA™ Adapters / General 2 Future consideration