Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4925

OPC Alarms&Events interface should allow to change fields pipe delimiter for PI points

When using a single PI tag, the fields are delimited by the pipe (|) symbol by default. It would be useful to change it to another delimiter or a combination of others. There could be messages containing this pipe (|) symbol, which would make it ...
Carlos Sola over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Allow modification of "head_end" in piscc.ini to modify naming convention for elements and tags.

When our EEAMAS Interface was originally implemented, the Head_End parameter was set to "Elster", the vendor name for our meters. So all of our meters from that interface are named Elster_xxx. Elster was purchased by Honeywell, so the name no long...
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Support capture of instrumentation values, such as "voltage" in the EEAMAS interface.

We are using this interface to capture meter attributes and measurements. However, the voltage comes in the XML files as an "instrumentation value", which is not currently supported. We would like to bring the voltage into a tag for the meter to u...
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Enhance the PI Perfmon interface to accept if the first character after the first bracket is #

Enhance the PI Perfmon interface to accept if the first character after the first bracket is # The counter path of NVidia's GPU temperature is \\computername\NVIDIA GPU(#0 Quadro M4000 (id=1, NVAPI ID=1280))\Temperature C. Enhance the PI Perfmon...
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Add OMF health to Citect interface

Add OMF health function to Citect interface.
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Export double-byte characters with HDATagBuilder

PI Interface for OPC HDA, as well as OPC HDA COM Connector, offer a tool called HDATagBuilder to collect all tags on an OPC HDA Server and export them to a CSV-file that can be used with PI Builder. This tool, however, is currently not able to co...
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Hitachi ABB Mach Interface

There are no current direct native interface connectivity to Hitachi ABB Mach systems. Current suggestion is to investigate IEC 61850 or Modbus could be investigated as an option.
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Update PI AMI Interface for OpenWay Collection Engine v1.8.1.124

Release a new version of the interface where it does not depend on the 1.x version of log4j rather the most recent and secure version of log4j. This is to improve security. Note: The Log4j 1.x version installed with the interface is not a part ...
Guest over 2 years ago in PI Interfaces / Other Interfaces 0 No status

Time shifting data to align with plant process flow and tank retention

This concept would really apply to all integrators except Esri.  We are careful to interpolate data in evenly spaced samples for large matrix analytics.  What happens when some of the data is upstream and the rest of the data is downstr...
Guest over 2 years ago in PI Integrators / General 0 Declined

Limit historical data retrieval for new elements

As a PI admin working with the integrator, I would like to be able to limit the amount of data returned for new elements added to existing views. This avoids the situation where a long-running view is unintentionally slowed when the integrator bac...
Guest over 2 years ago in PI Integrators / General 0 Declined