To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ Adapters

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Allow setting interpolation type in Adapters

We would like to be able to specify the interpolation type (linear vs step) when Adapter creates tags in Archive.
Damon Vinciguerra about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

processor rate(s) for Processor properties of Modbus Adapter Service Health

Visualize and understand usage when trended with other diagnostic properties.
Guest 3 months ago in AVEVA™ Adapters / General 1 No status

OMF Egress health to include stream count

Validate stream count for scenarios where there are multiple Components
Guest 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Design some UI for PI Adaptors

Design some UI for PI Adaptors, so it will be user friendly to configure the data source or data reading configurations etc. It is really hard to configure or troubleshoot an issue in PI Adaptor without Proper UI.
PradeepKumar Logandurai over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 2 No status

Support "Data Handling" options for adapters

The PI Interface for OPC DA can write IO timeout when it cannot get values from the OPC server. It would be useful to have the same option for the adapters so that stale data is marked IO timeout or similar, and automatically invalidates calculati...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / General 1 No status

Egress via AF SDK

Please add AF SDK Egress as an additional optional egress component. This would be very helpful for customers who are using the adapters, but keeping the PI Server on-premise. The adapters are relatively light-weight services; however, the “cost” ...
sahilp 12 months ago in AVEVA™ Adapters / General 1 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Add a parameter for the Adapter to increase the Keep-Alive wait time

Currently, there is no parameter on the Adapter side to increase the Keep-Alive wait time. It would be best to add parameter for the Adapter to increase the Keep-Alive wait time.
Alexa Derago 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status